P## Buzz On Fault
Default:
0
Selection:
0 to 3
Selection
Operation for Controlled Points
(Point Types 1, 2, and 3)
Operation for 24-hour, Fire and Aux AC
Supervision Points (Point Types 0 and 11)
0
The point buzzes at the keypad only if it
enters into the trouble condition indicated in
the
P## Point Response
.
Same as operation for controlled points
1
The point generates a Buzz Until Restore at
the keypad for
any fault condition
while the
point is disarmed
. The buzz continues until
the point restores and the user acknowledges
the condition using a passcode or COMMAND
4. The point must be normal before the user
can silence the buzz.
The point generates a Buzz Until Restore at
the keypad for
any fault condition
regardless of the armed state
. The buzz
continues until the point restores and the user
acknowledges the condition using a passcode
or COMMAND 4. The point must be normal
before the user can silence the buzz.
2
The point buzzes at the keypad for
any fault
condition
when the point is disarmed
. The
user can silence the buzz before the point
returns to normal.
The point buzzes at the keypad for
any fault
condition regardless of the armed state
.
The point does not need to be normal before
the user can silence the buzz.
3
The point buzzes at the keypad for any fault
condition when the area is disarmed. The
user cannot silence this buzz, but it silences
automatically when the point is restored. If the
fault condition results in a trouble response,
the keypad continues to buzz even after the
user acknowledges the condition if the fault is
still present.
The point buzzes at the keypad for
any fault
condition regardless of the armed state
.
The user cannot silence this buzz, but it
silences automatically when the point is
restored. If the fault condition results in a
trouble response, the keypad continues to
buzz even after the user acknowledges the
condition if the fault is still present.
Points bypassed (by the user, Sked,
Swinger Bypass, or RPS) do
not
generate a Buzz On Fault condition at the
keypad.
The buzz does not automatically stop
when the point is restored when using
Option 1 or 2. The user must
acknowledge the buzz before the buzz
stops. However, when using Option 3,
the buzz stops automatically when the
point restores to normal without user
intervention.
P## Watch Point
Default:
Refer to the program record sheet
Selection:
Yes or No
Yes
Activates Watch Mode responses if
the point is faulted while the control
panel is in Watch Mode.
No
Does not activate Watch Mode
responses for this point.
Use this option to allow a Controlled point to generate
a watch tone while the area is disarmed and not
faulted to a trouble or alarm condition.