![Bosch D7212GV3 Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/bosch/d7212gv3/d7212gv3_program-entry-manual_39294056.webp)
D7212GV3 |
Program Entry Guide | 2.0
Panel and Area Wide Parameters
EN
| 56
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Delay arms all Perimeter points in the area where the
keypad is assigned. Entry and exit delays are
provided with this Arming function. This function does
not cause a Perimeter Instant point to act as a Delay
point.
Watch Mode
Default:
E
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
6 Watch
Mode
[COMMAND][6]
This function informs you when a perimeter point or
interior point that is programmed as
P## Watch
Point
is faulted while the area is disarmed. Interior
points do not emit a Watch Tone if the area is
perimeter armed. This function provides keypad
audible or visual and optional relay activation (refer to
A # Watch Mode
in
Section 2.12.1 Area Relays
on
page 70).
Perimeter Partial
Default:
P
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
7
Perimeter Partial
Arm
[COMMAND][8]
Use this function to arm normal perimeter points and
force-bypass faulted perimeter points, regardless of
their P## Bypassable setting. When these force-
bypassed perimeter points return to normal, they
automatically return to service, even if P## FA
Returnable is set to No.
Perimeter Partial arming has entry and exit delays.
Perimeter Partial
ignores the
A# Force
Arm/Bypass Max
entry in
Section 2.8
Area Parameters
on page 31.
Local Only Reporting:
No Closing
Report is sent to the central station, but a
Perimeter Delay Closing Event is
generated in the event log.
View Area Stat
Default:
P
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
8
View Area Status
(Menu function
only)
Use this function to view the armed status of all areas
within the scope of the keypad assigned to this area.
The armed states include A# AREA # IS OFF
(disarmed), A# AREA # IS ON (master delay armed),
ALL ON INSTANT (master instant armed), and AREA
# PERIMETER ON (perimeter instant armed or
perimeter delay armed). All area types, master,
associate, regular, and shared can be viewed using
this function.
View Memory
Default:
E
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
9
View Event
Memory
[COMMAND][4][0]
Use this function to view prior alarm, trouble, and
supervisory activity occurring since the last time the
system armed. Event memory is not cleared until the
area re-arms.
View Point Status
Default:
E
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
10
View Point Status (Menu function
only)
Use this function to view points assigned to the area
where the keypad is assigned. This function shows
point text and the electrical condition (normal, open,
short, and missing) of each point in the area.
Walk Test
Default:
E
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
11 Walk
Test
[COMMAND][4][4]