D7212GV3 |
Program Entry Guide | 5.0
Schedules (Skeds)
EN
| 106
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Default:
0
Selection:
0 to 24, 28, 29
S## Relay Number
Blank
No relay is
activated.
6
Relay On:
This function emulates
the Change Relay keypad function to
turn relays on. The entry in the
S##
Relay Number
prompt defines the
specific relay this sked activates.
The sked can activate one relay.
Default: Blank
Selections: Blank,
1 to 24
Enter the number of the relay
the sked activates
1 to 24
Relay to
activate.
S## Relay Number
Blank
No relay is
turned off.
7
Relay Off:
This function emulates
the Change Relay? keypad function
to turn relays off. The entry in the
S## Relay Number
prompt defines
the relay this sked turns off. The
sked can turn off only relays that are
set by a sked. The sked can turn off
one relay.
Default: Blank
Selections: Blank,
1 to 24
Enter the number of the relay
that turns the sked off.
1 to 24
Relay to turn
off.
8
All Relays Off:
This function is not available as a keypad function. This sked function turns off all
relays that are turned on by a sked. This is a panel-wide function.
No other parameters require input for this option.
S## Defer Test
Yes
Defer the Test
Report.
Default: No
Selection: Yes or No
Enable sked to defer the Test
Report
No
Send the Test
Report on
schedule.
S## Hourly Report
Yes
Send the Test
Report every
hour.
9
Test Report:
This function emulates
the
Test Report?
sub-function of the
Send Report?
keypad function
([COMMAND][4][1]). This function
generates a Test Report
only
from
Area 1 but contains panel-wide status
information. The report is sent to the
phone(s) programmed for Test and
Status Reports in
Section 2.3.8
Communication Attempts
on page 14.
If
Expand Test Prt
in
Phone
parameters is programmed as
Yes
,
the Test Report also includes all off-
normal states for events listed in
Diagnostic Reports and Test Reports
(refer to
Section 2.3.8 Communication
Attempts
on page 14).
The Test Report can be deferred if
any other report was sent since the
last Test Report. To defer the Test
Report, program
S## Defer Test
.
The Test Report can be sent every
hour beginning at the time scheduled
in
S## Time
. To send a Test Report
every hour, program
S## Hourly
Report
.
Default: No
Selection: Yes or No
Select Yes to send the Test
Report every hour.
No
Send the Test
Report only as
scheduled.