Schedules (Skeds)
EN
| 105
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Default:
0
Selection:
0 to 24, 28, 29
S## Area 1[through 4]
1
Arm Area:
This function emulates
the Master Arm Delay keypad
function. Entries in the
S## Area #
prompts define the area(s) this sked
arms. The sked can arm multiple
areas. If any point is faulted when
the sked executes, it is force armed
regardless of the
A# Force
Arm/Bypass Max
setting.
Default: No
Selections: Yes or No
Enable the sked to arm the
areas indicated with
Yes
.
Yes
No
Arm Area #.
Do not arm Area #.
S## Area 1[through 4]
2
Disarm Area:
This function
emulates the DISARM #? Or
DISARM ALL? Keypad function list
options. Entries in the
S## Area #
prompts define the area(s) this sked
disarms. The sked can disarm
multiple areas.
Default: No
Selection: Yes or No
Enable the sked to disarm the
areas indicated with
Yes
.
Yes
No
Disarm Area #.
Do not disarm
Area #.
S## Point Number
3
Bypass a Point:
This function
emulates the Bypass Point? keypad
function. The entry in the
S## Point
Number
prompt defines the point
this sked bypasses. The point can be
bypassed only if
Bypassable
is
programmed
Yes
in the point index
assigned to the point. The bypass is
reported if the Bypass Reports is
enabled by the point index settings
assigned to the point. The sked can
bypass one point.
Default: Blank
Selections: Blank, 1 to 40
Enter the number of the point
the sked bypasses.
Blank
(0)
1 to 40
No point is
bypassed
Point to bypass
S## Point Number
4
Unbypass a Point:
This function
emulates the Unbypass Point?
keypad function. The entry in the
S## Point Number
prompt defines
the point this sked unbypasses. The
sked can unbypass one point.
Default: Blank
Selections: Blank, 1 to 40
Enter the number of the point
the sked unbypasses.
Blank
(0)
1 to 40
No point is
unbypassed.
Point to unbypass.
S## Area 1[through 4]
Yes
Unbypass all
points in Area #.
5
Unbypass All Points:
This function
is not available as a keypad function.
The entry in the
S## Area #
prompt
defines the area(s) where the sked
unbypasses all points. The sked
unbypasses all points in the area,
regardless of how they were
bypassed. This sked can unbypass
all points in multiple areas.
Default: No
Selection: Yes or No
Select Yes to unbypass all
points in the areas indicated.
No
Do
not
unbypass
all points in
Area #.