D7212GV3 |
Program Entry Guide | 5.0
Schedules (Skeds)
EN
| 107
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Default:
0
Selection:
0 to 24, 28, 29
S## Defer Status
Yes
Defer the Status
Report.
10
Status Report:
This function
generates a Status Report for each
area that is enabled. The report is
sent to the phone(s) programmed for
Test and Status Reports in Routing.
The Status Report can be deferred if
any other report was sent since the
last Status Report. To defer the
Status Report, program
S## Defer
Status
.
Default: No
Selection: Yes or No
Enable sked to defer the
Status Report.
No
Send the Status
Report on
schedule.
S## Cmd Center
Blank (0)
No keypad is
specified for
Custom Function
activation.
Default: Blank (0)
Selections: Blank (0), 1 to 8
Identify the specific keypad
(CC #) where the Custom
Function is entered. Only one
keypad can be assigned for
this sked function.
1 to 8
Command
center (keypad)
address
specified for
Custom Function
activation.
S## Custom Func
Blank (0)
No Custom
Function is
activated.
Default: Blank (0)
11
Execute Custom Func
: This
function emulates any of the custom
functions assigned to the keypad
that can be executed by a user from
the keypad. When a sked executes a
custom function, it is subject to the
scope of the selected keypad.
Cmd
Center
and
Custom Func
prompts
appear after entering Function Code
11. Both entries are required.
Selections: Blank (0),
128 to 131 for D7212GV3
Enter the custom function this
sked executes.
128 to
131
Custom Function
to activate.
12
Contact RPS
: This function attempts to contact an Unattended
RPS at the configured time. The control panel’s account in RPS
controls the operations performed upon successful contact.
Avoid having multiple functions occur at the same time at the same address. Functions can clash and the
effect on the control panel is unpredictable.
Ensure that the Custom Function being executed or any of the commands nested inside the Custom
Function are not passcode protected.
Do not program multiple skeds to execute at the same keypad during the same time.
Do not program skeds to execute at times when a user is likely to be executing functions at the keypad. If it is
necessary to do so, there are two ways to work around the situation:
1.
For a D1255 keypad type, program "
C
","
C
"at the beginning of the Custom Function Key Strokes entry.
This aborts the user’s function and allows the sked to execute.
2.
Program the sked to execute at an address (Cmd Center) with no keypad physically attached to it. The
CC # must be assigned to an area and have the appropriate scope programmed.
(Continued on next page.)