D1260/D1260B
|
Installation Guide | 2.0
D1260/D1260B Overview
8
Bosch Security Systems | 9/04 | 48101E
2.3 Internal
Features
To access the inside of the D1260/D1260B, the back plate must be removed. Using a small flat-blade screwdriver,
gently push in the two holes in the bottom of the D1260/D1260B. As the tabs are pushed in, lift the back plate
away from the rest of the unit.
Figure 4:
D1260/D1260B with Back Plate Removed
ON
CTS
1
2
3
4
5
6
1
2
4
5
3
1 - DIP switch (Six-position) - allows you to select the
address of each keypad, and enable/ disable the
keypad encoding tone.
(refer to
Section 3.2 Setting the DIP Switch
on
page 10).
2 - EEPROM socket (with example EEPROM
installed)
3 - Volume control potentiometer
(refer to
Section 3.4 Volume Control
on
page 10)
4 - Wall tamper switch
(refer to
Section 3.3 Tamper Switch
on
page 10)
5- SDI connector jack