background image

D1260/D1260B 

|

 

Installation Guide | 4.0  

Programming the Control Panel 

 

Bosch Security Systems | 9/04 | 48101E 

13 

 

4.2 

Programming Area Names 

When the D1260/D1260B is installed with Bosch 
Control Panels, Points 240 to 247 are used for the Area 
Text Name for the Area (1 to 8) that the keypad is 
assigned to. When the D1260/D1260B is installed with 
the D7212G Control Panel, Points 240 to 243 can be 
used for Area Text Name for the Area (1 to 4) that the 
keypad is assigned to. 

Points 240 to 247 can still be used in D9412 and 
D9112 systems to detect alarms, although any custom 
point text that is point specific is displayed as the Area 
Name Text. 

For example, if a D1260/D1260B is assigned to Area 1, 
and the name of Area 1 is “WAREHOUSE,” then you 
would program the word “WAREHOUSE” into Point 
240. 

Refer to 

Table 8

 for Area Name Text assignments. This 

point text is used in the Bosch Control Panels to 
program the Area Names. 

 

Table 8: 

Area/Point Numbers and Area Text 

 

Area 

Pt # 

Area Name Text – up to 16 characters 

1* 

240 

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 

2* 

241 

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 

3* 

242 

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 

4* 

243 

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 

244 

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 

245 

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 

246 

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 

247 

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 

*D7212G uses Points 240 to 243 for Area Name Text. 

4.3 

Programming Security Company 
Information

 

Select Security Co. Info from the D1260/D1260B’s 
Help? menu to enter your security company’s phone 
number in case a subscriber needs to contact you.  

4.3.1 

D9412G, D9412 and D9112 Control Panels 

If the keypad is connected to the D9412G, D9412 or 
D9112 Control Panel, use the following steps to 
program your security company’s name and phone 
number. 
1.

Double-click on the RPS icon. 

2.

Enter a valid username and password. 

3.

Double-click on the desired control panel. 

4.

Under “D9412 Program Record Sheet” locate the 
section called “PASSCODES 
(RADXUSR1/RADXUSR2)”. 

 

5.

Under Passcodes & Authority Levels, select Users 
201 - 249. 

 

6.

Scroll down the rows of Users to row User 249. 

 

7.

Double-click on the User 249 cell. 

A dialog box appears asking to change the text 
USER 249. 

 

8.

Type the phone number of the security company. 

9.

Click 

OK

 to finish. 

 

Содержание D1260 Series

Страница 1: ...EN Installation Guide Keypads D1260 D1260B ...

Страница 2: ...emarks Microsoft Windows Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries CYCOLOY is a registered trademark of General Electric Company POLYLAC is a registered trademark of CHI MEI Industrial Corporation LTD ...

Страница 3: ...tup Function 14 4 5 Programming Custom Functions 14 4 6 Adding Service Walk to D7412G D7412 D7212G D7212 Service Menu 14 5 0 Specifications 16 Figures Figure 1 D1260 D1260B Front Panels 5 Figure 2 D1260 D1260B LCD Display 6 Figure 3 D1260 D1260B Keypad 6 Figure 4 D1260 D1260B with Back Plate Removed 8 Figure 5 D1260 D1260B Back Plate Mounting Options 9 Figure 6 D1260 D1260B DIP Switch 10 Figure 7 ...

Страница 4: ...412G D7412G Program Entry Guide 47775 D9412G D7412G Program Record Sheet 47488 1 3 Documentation Conventions 1 3 1 Type Styles Used in this Manual Bold text Usually indicates selections that you can use while programming your control panel or an important fact that you should note Bold Italicized Denotes notes cautions or warnings Italicized text Refers you to a drawing table another section of th...

Страница 5: ...c control panel used with the D1260 D1260B to determine if you need an additional power supply You can program the control panel to send messages identifying the supervised keypad that is in trouble to a central station receiver To supervise a keypad refer to the program entry guide specific to your control panel If a keypad loses communication with the control panel for more than 15 sec the keypa...

Страница 6: ...eypad The D1260 D1260B Keypad features a digital keypad for entering user passcodes and executing system commands in the control panel Figure 3 D1260 D1260B Keypad D1260 D1260B Please refer to the Security System User s Guide P N 4998122475 for instructions on operating the system When a key is pressed the D1260 D1260B emits a muted beep tone refer to Section 2 2 4 Audible Tones on page 7 to indic...

Страница 7: ...d emits a steady high pitched bell tone Entrance Warning The keypad emits an intermittent beep tone during entry delay periods to remind the user to disarm the area This is a programmable option Exit Warning The keypad emits an intermittent beep tone during exit delay This is a programmable option Invalid Key Buzz When an invalid key or sequence of keys is pressed the keypad emits a flat buzz tone...

Страница 8: ...in lift the back plate away from the rest of the unit Figure 4 D1260 D1260B with Back Plate Removed ON CTS 1 2 3 4 5 6 1 2 4 5 3 1 DIP switch Six position allows you to select the address of each keypad and enable disable the keypad encoding tone refer to Section 3 2 Setting the DIP Switch on page 10 2 EEPROM socket with example EEPROM installed 3 Volume control potentiometer refer to Section 3 4 ...

Страница 9: ...d Flush Mount Kit Brass D54C 1260 Keypad Flush Mount Kit Stainless 3 1 1 Location Recommendations Do not mount the keypad in a location in direct sunlight Direct sunlight can interfere with the D1260 D1260B display screen visibility and damage internal components Do not mount the D1260 D1260B in wet or moist locations Figure 5 D1260 D1260B Back Plate Mounting Options 1 1 1 2 2 3 3 3 3 4 4 4 4 5 1 ...

Страница 10: ... access the DIP switch remove the back cover Switches 1 through 3 assign the address for the specific keypad Figure 6 D1260 D1260B DIP Switch ON 1 2 3 4 5 6 Assign each D1260 D1260B Keypad to a unique address and supervise the keypad Switch 5 toggles the encoding tone ON and OFF With the encoding tone turned ON the keypad sounds a beep every time a key is pressed Always keep Switch 4 and 6 ON Tabl...

Страница 11: ... page 10 2 Connect the flying leads of the wiring assembly provided to the wires from the control panel as shown in Figure 9 Figure 9 Bosch Control Panel to Keypad Flying Leads Wiring POWER 32 DATA BUS A 31 DATA BUS B 30 COMMON 29 1 2 3 4 6 5 1 Represents the entire length between control panel and keypad 2 SDI connector jack on keypad 3 SDI power 4 SDI Data Bus A 5 SDI Data Bus B 6 SDI common 3 T...

Страница 12: ...nd Center Figure 11 Figure 11 Enhanced Command Center Prompt in RPS 6 Change Enhanced Command Center for the keypad address to Yes When toggling the parameter from No to Yes reset the control panel to ensure it takes effect Figure 11 assumes the keypad is CC Address 1 For more information refer to the control panel s program entry guide 7 The Display Revision Command 59 function under USER INTERFA...

Страница 13: ...__ __ __ __ __ __ __ __ __ __ __ 3 242 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 4 243 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 5 244 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 6 245 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 7 246 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ 8 247 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ D7212G uses Points 240 to 243 for Area Name...

Страница 14: ...s and contrast Figure 13 to Figure 15 Figure 13 High Brightness Settings Figure 14 Low Brightness Settings Figure 15 Contrast Settings Each of these selections have Level soft keys on either side of the display that allows you to increase or decrease the setting The High and Low Brightness are associated with Command 49 s Bright Display and Dim Display settings This menu also shows the Keypad addr...

Страница 15: ...000MAIN in the D7412 Program Record Sheet tree 10 In the pane below scroll down the menu list to the next open Menu Item space for the keypad assuming it is CC Address 1 11 Double click on the 0 cell to open a dialog box to change the Function number 12 Enter a Data Value from 0 to 33 13 Click OK Menu Item 15 is now set to Function 33 but still does not appear in the keypad menu 14 Double click on...

Страница 16: ...4 6 in x 8 2 in x 0 8 in D1260B 12 6 cm x 21 cm x 3 2 cm 5 0 in x 8 2 in x 1 3 in Weight 439 g 15 5 oz D1260 Off white D1260B Off white and dark gray D1260BLK Black D1260R Red Color D1260W White Material D1260 GE CYCOLOY CH10 UL94 HB Fire Rated D1260B CHI MEI POLYLAC PA 747 with UV Stabilizer UL94 HB Fire Rated Enclosure Environmental Intended for indoor use Operating 0 C to 49 C 32 F to 120 F Tem...

Страница 17: ...D1260 D1260B Installation Guide 5 0 Specifications Bosch Security Systems 9 04 48101E 17 Notes ...

Страница 18: ...D1260 D1260B Installation Guide 5 0 Specifications 18 Bosch Security Systems 9 04 48101E Notes ...

Страница 19: ...D1260 D1260B Installation Guide 5 0 Specifications Bosch Security Systems 9 04 48101E 19 Notes ...

Страница 20: ... 2004 Bosch Security Systems 48101E Bosch Security Systems 130 Perinton Parkway Fairport NY 14450 9199 Customer Service 800 289 0096 Technical Support 888 886 6189 ...

Отзывы: