D1260/D1260B
|
Installation Guide | 4.0
Programming the Control Panel
.
Bosch Security Systems | 9/04 | 48101E
15
5.
Scroll down the list of commands in the lower
pane to “(33) Service Walk - (Use 99 + Enter
key).”
6.
Double-click on the
P
cell.
A dialog box appears with the different settings for
the Service Walk command.
For the D7412G, D7412, D7212G, and D7212
Control Panels, the Service Walk command must
be set to E (enabled) or P (password enabled) to be
accessible from the D1260/D1260B Keypad.
7.
Click on either
E
or
P
.
8.
Click
OK
.
9.
Select “FUNCTION LIST (9000MAIN)” in the
D7412 Program Record Sheet tree.
10. In the pane below, scroll down the menu list to the
next open Menu Item space for the keypad
(assuming it is CC Address 1).
11. Double-click on the
0
cell to open a dialog box to
change the Function number.
12. Enter a Data Value from 0 to 33.
13. Click
OK
.
Menu Item 15 is now set to Function 33 but still does
not appear in the keypad menu.
14. Double-click on the yellow
No
cell to open a
dialog box to change the value.
15. Select
Yes
and click
OK
to exit.
A green
Yes
cell appears next to the Menu Item.
16. Follow
Steps 10
to
12
in
Section 4.3.1 D9412G,
D9412 and D9112 Control Panels
on page 13 to
update the control panel.
The Service Walk command now appears in the
D1260/D1260B Keypad display
Содержание D1260 Series
Страница 1: ...EN Installation Guide Keypads D1260 D1260B ...
Страница 17: ...D1260 D1260B Installation Guide 5 0 Specifications Bosch Security Systems 9 04 48101E 17 Notes ...
Страница 18: ...D1260 D1260B Installation Guide 5 0 Specifications 18 Bosch Security Systems 9 04 48101E Notes ...
Страница 19: ...D1260 D1260B Installation Guide 5 0 Specifications Bosch Security Systems 9 04 48101E 19 Notes ...