Fortessa_FTK5_Instructions_Rev01 

 

 

 

FTK5 PROXIMITY KEYPAD 

Before using the unit, please read the instructions and retain for future reference 

 

 

 

 

 

 

Summary of Contents for FTK5

Page 1: ...Fortessa_FTK5_Instructions_Rev01 1 FTK5 PROXIMITY KEYPAD Before using the unit please read the instructions and retain for future reference ...

Page 2: ...ob card and user code From quiescent state Constant Blue LED default Enter programming code default 1234 1 2 3 4 1 2 3 4 unless changed Long beep Yellow LED Enter user ID from 001 600 i e 0 0 2 alternating flashing green amber if you hear a double bleep and constant green LED then the user ID has already been programmed and will require deleting first before programming Enter user code X X X X X C...

Page 3: ...hanged Long beep Yellow LED Enter 0 0 0 double bleep constant amber LED Enter New Programming code X X X X To Insert a Programming Card Fob This Card Fob will not operate the Lock This card fob will only allow access to the programming menu functions and will not operate the lock output From quiescent state Constant Blue LED default Enter programming code default 1234 1 2 3 4 1 2 3 4 unless change...

Page 4: ...e entered will permanently override the lock until the Toggle code has been re entered i e for deliveries Note For the toggle code to operate the Toggle Mode will need to be set This mode NOT suitable for failsecure locks From quiescent state Constant Blue LED default Enter programming code default 1234 1 2 3 4 1 2 3 4 default unless changed Enter 8 5 4 X X X X X Bypass Code Change Toggle Mode def...

Page 5: ...rbell button which operates AUX Output 4 Tamper activated Operates the AUX output 5 Door forced Door opened reed activation with correct code fob or push button activation 6 Activate P B Operates AUX Output when the push button has been operated 7 AUX Code AUX code entered activates output If the AUX output time is left at 000 then operation will not work AUX Output Mode See table above From quies...

Page 6: ...Fortessa_FTK5_Instructions_Rev01 6 1 Gang Box ...

Page 7: ...c Lock Failsafe Wiring Diagram DLU1 Lock Failsecure 12 24v AC DC AL O P COM REED P B NC C NO Lock Output NC C NO AUX Output 12V DC PSU 230V SUPPLY If door contact or reed switch is not used then ensure the Reed jumper is inserted DLU1 Failsecure Lock Varistor ...

Page 8: ...r Example 0214561967 028 Mrs J Smith 000 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 For Additional fobs please use blank sheet on following page ...

Page 9: ...Fortessa_FTK5_Instructions_Rev01 9 Fob or Card ID Number Keypad User Number Named Holder ...

Page 10: ...klight 8 5 9 1 Open 8 8 8 None Specification 26Bit card 26 34Bit Power AC DC 12 24V 10 Power consumption 3W Lock Out volt free change over contacts Max 24v 3A Aux Out volt free change over contacts Max 24v 3A AL Out Alarm Sw output Max 12v 500mA Weight 0 56kg Size 79 W x 79 H x 28 D Card EM induction card 125 KHz Due to our policy of continuous improvement we reserve the right to change specificat...