20

INSTALLATION
The appliance must be installed by qualifi ed staff working in ac-
cordance with the regulations in force.
Before installing, ensure that the appliance is correctly preset for 
the local distribution conditions (gas type and pressure).
The presettings of this appliance are indicated on the nameplate 
shown on the cover.
This appliance is not connected to a fl ue gas extractor device. It 
must  be  installed  and  connected  in  accordance  with  the  regula-
tions in force.
This appliance may only be installed and may only operate in rooms 
permanently ventilated in accordance with national regulations in 
force.

VENTILATION
The rooms in which gas appliances are installed must be well ven-
tilated in order to allow correct gas combustion and ventilation.
The air fl ow necessary for combustion is at least 2 m

3

/h for each 

kW of rated power.

POSITIONING
Remove the packaging accessories, including the fi lms covering the 
chrome-plated and stainless steel parts, from the cooker. 
Position the cooker in a dry, convenient and draft-free place. Keep 
at an appropriate distance from walls which may be damaged by 
heat (wood, linoleum, paper, etc.).
The cooker may be free-standing (class 1) or between two units (in 
class 2 st 2-1) the sides of which must withstand a temperature of 
100°C and which must not be higher than the working table, in the 
event of different installation arrangements with a side wall above 
the working table, the wall must be at least 20 cm from the top of 
the appliance.

FITTING THE FEET (present only in a few models)
Cookers are equipped with adjustable feet to be screwed into their 
front and rear corners respectively. The feet allow the height of the 
appliance to be adjusted, in order to set it fl ush with the adjoining 
unit, to level it with other worktops and to ensure even distribution 
of the liquids in pans. See fi g. 18

CONNECTING TO THE GAS SUPPLY
Before connecting the cooker, check that it is preset for the gas 
to be used. Otherwise, make the conversion as described in the 
section headed “Adapting to different gas types”. The connection 
is on the right; if the pipe has to pass behind the cooker, it must be 
kept low down where the temperature is about 50°C.
- Rigid connection (see fi g. 3 A + B)
  The connection to the mains gas supply may be made using a 

rigid metal pipe or with a metal hose. Remove the hose connec-
tor (if already fi tted) and screw the rigid union onto the threaded 
connection of the gas train (see fi g. 3A). The union for rigid con-
nection may already be fi tted on the gas train, or may be amongst 
the cooker accessories. Otherwise, it can be obtained from your 
dealer.

  If  national  regulations  permit,  a  metal  hose  complying  with  the 

national  standards  can  be  screwed  directly  onto  the  threaded 
connection of the gas train, fi tting a seal (see fi g. 3B). However, 
users are strongly recommended always to fi t the rigid union.

-  Connection using a rubber hose (see fi g. 3C).  (For butane/propane 

gas only).

  Connect a rubber hose carrying the conformity mark currently in 

force to the hose connector. The hose must be replaced at the 
date indicated at the latest, and must be secured at both ends 
using standard hose clamps. It must be absolutely accessible to 
allow its condition to be checked along its entire length.

CAUTION:
- Use of the hose connector is only permitted for free-standing in-

stallation.  If the appliance is installed between two class 2 st. 2-1 
unions, the rigid union is the only form of connection permitted.

IMPORTANT:
- After installation, check that the connections are airtight.
- For operation with butane/propane, check that the gas pressure 

is as indicated on the nameplate.

- Use  only  standard  rubber  hoses.    For  LPG,  use  a  hose  which 

complies with the national regulations in force.

- Avoid sharp bends in the pipe and keep it well way from hot sur-

faces.

References to the regulations covering the gas connection to the 
appliance: ISO 7-1.

ADAPTING TO DIFFERENT TYPES OF GAS
- Remove the grid, the burner caps (A),  and the burners (B);
- Unscrew and remove the injector in the bottom of each injector 

holder (C);

- replace the injector in accordance with the table in page 19 using 

a 7 mm socket wrench,  tighten and screw right down;

- check that the system is gas-tight;
- replace the burners, the burner caps and the grid.
IMPORTANT:
- Never over-tighten the injectors;
- after replacing, check that all the injectors are airtight.

REPLACING THE HOB BURNER INJECTORS (Fig. 4)
- Remove the lid of the cooker by lifting it off its supports;
- remove the grids, burner caps and burners, lifting them off;
- unscrew the 2 screws (above) or nuts (below) at the back which 

secure the work top, and pull it out forward.

- remove the mixer pipes and replace the injectors using a 7 mm 

socket wrench.

REPLACING THE OVEN BURNER INJECTOR (Fig. 5)
- Loosen the screw which secures the bottom of the oven;
- remove the oven bottom (pulling it forward);
- remove the oven burner, after taking out the screw which secures 

it;

- replace the injector using a 7 mm socket wrench.

REPLACING THE GRILL BURNER INJECTOR (Fig. 6)
- Remove the burner after taking out the two screws which secure 

it;

- replace the injector using a 7 mm socket wrench.
IMPORTANT:
- Never over-tighten the injectors;
- after replacing, check that all the injectors are airtight.

REGULATING THE BURNER AIR
Refer to the table below (indicative values) for regulation of the gap 
H in mm (fi g. 6 for the grill).

 Burner

G20 20mbar
G25 25mbar

G30 28-30mbar

G31 37mbar

 Oven
Grlll 

-

4

-

8

  

Check operation of the burner:
- Ignite the burner at maximum fl ame;
- the tongue of the fl ame must be clear and with no yellow tip, and 

must adhere closely to the burner.  If too much air is supplied, 
the fl ame detaches from the burner and may be dangerous.  If 
the air supply is insuffi cient, the fl ame has a yellow tip and soot 
may form.

SETTING HOB BURNER MINIMUM LEVELS
If the cooker is to work on bottled gas (butane/propane), the tap 
by-pass must be screwed right down.
The cooker may be equipped with type A taps, with by-pass inside 
(accessed by inserting a small screwdriver into the rod) or type B 

Installation

GB

Содержание 50 N SERIES

Страница 1: ...isini res gaz mixtes et lectrique S ries Instructions for use and maintenance of gas gas electric and electric cookers Series Rukovodstvo po ustanovke i kspluatacii gazovyx kombinirovannyx i lektrihes...

Страница 2: ...a 73 23 CEE e suc cessivi emendamenti CEE 2004 108 Radiodisturbi Regolamento Europeo 1935 2004 materiali a contatto con alimenti Regolamento Europeo 1275 2008 consumo energia in stand by e off mode CE...

Страница 3: ...a carico normale ventilato in minuti 55 8 55 8 Consumo posizione stand by in watt Superficie utile del pianodi cottura leccarda in cm2 1156 1156 1156 Dati e caratteristiche tecniche BRUCIATORI A GAS i...

Страница 4: ...ne di tenuta fornita in dotazione Raccordo con tubo in gomma su portagomma vedi Fig 3 C e D Si effettua con un tubo in gomma che porta il marchio di conformit alla norma in vigore Il tubo deve essere...

Страница 5: ...pareti calde che siano su periori a 75 C in caso di sostituzione del cavo deve essere di tipo H05RR F o H05V2V2 F con sezione adeguata vedere schemi in fig 2 in caso l apparecchio sia fornito senza ca...

Страница 6: ...nopola sulla posizione di minimo fiamma piccola Per le cucine munite di accensione elettrica ai bruciatori forno e grill imperativo accendere questi bruciatori con la porta del forno totalmente aperta...

Страница 7: ...zionale forno statico la temperatura del forno viene regolata mediante la manopola del termostato simbolo accensione grill NOTA La spia gialla si accende secondo l intervento del termo stato Prima di...

Страница 8: ...ndole nella posizione 1 6 Chiudere normalmente la porta USO ACCESSORI DEL FORNO La griglia del forno serve a supportare teglie di commercio per con tenere dolci arrosti o direttamente le carni da cuoc...

Страница 9: ...quivalente L utente responsabile del conferimento dell apparecchio a fine vita alle appropriate strutture di raccolta pena le sanzioni previste dalla vigente legislazione sui rifiuti L adeguata raccol...

Страница 10: ...n 1935 2004 17 Figures 58 60 FR Nous vous remercions d avoir choisi un appareil de notre mar que Veuillez lire attentivement cette notice pour b n ficier des performances que vous tes en droit d en a...

Страница 11: ...de la notice seulement pour les produits gaz ou mixtes Informations utiles pour la consommation nerg tique des fours lectriques Ces informations compl tent celles de la fiche technique autocol lant et...

Страница 12: ...norme NF GAZ Le tube est changer la date indiqu e et doit tre fix aux extr mit s par des colliers de serrage normalis s et doit tre absolu ment contr lable sur toute sa longueur Le raccordement gaz av...

Страница 13: ...entrer en contact avec des parties chaudes qui soient sup rieures 75 C en cas de changement du c ble il doit tre du type H05RR F ou H05V2V2 F de section correcte voir sch mes fig 2 si l appareil est...

Страница 14: ...ifficile pour quelques types de gaz il est conseill d effectuer l op ration avec la manette sur position minimum flamme au ralenti Pour les cuisini res quip es de dispositif d allumage lectrique des b...

Страница 15: ...es aiguilles d une montre on assure successivement les op rations suivantes symbole clairage de la lampe du four elle restera toujours allum e sur toutes les diff rentes positions de la manette symbol...

Страница 16: ...mpl tement la porte 2 Faire passer les deux leviers B de la position 1 la position 2 voir fig 17 3 Refermer lentement la porte jusqu la but e la prendre des deux mains l une du c t gauche et l autre d...

Страница 17: ...u recyclage du mat riel lectrique et lectronique ou bien tre remis un revendeur au moment de l achat d un nouvel appareil quivalent L utilisateur est responsable de la remise de l appareil en fin de v...

Страница 18: ...75 2008 EEC 40 2002 EEC 92 75 2002 96 EC WEEE 2005 32 CE Energy using Products FOREWORD Refer only to the headings and sections covering accessories actually installed on your cooker Technical data an...

Страница 19: ...minutes 55 8 55 8 Power consumption in stand by setting in Watts Usable area of the dripping pan in cm2 1156 1156 1156 Technical data and specifications GB ELECTRIC HOTPLATES 145 1 0 kW Normal hotplat...

Страница 20: ...r butane propane gas only Connect a rubber hose carrying the conformity mark currently in force to the hose connector The hose must be replaced at the date indicated at the latest and must be secured...

Страница 21: ...st be used for the earth connection the blue wire is the neutral the brown wire is live the lead must never touch hot surfaces over about 75 degrees C replacement leads must be of type H05RR F or H05V...

Страница 22: ...has not lit after these 10 seconds stop using the device leave the door open and wait one minute before trying again to ignite the burner If the ignition device malfunctions again light the burner wi...

Страница 23: ...to the other settings symbol operation of fan symbol cooking with fan oven on one or two levels the oven temperature is controlled using the thermostat knob symbol grill on N B The yellow light switc...

Страница 24: ...uced mental or motor capacities including children or by those who are not ex perienced or know how to work it unless supervised or instructed on its use by safety personnel Children must be supervise...

Страница 25: ...nt and compatible environmental disposal contributes to avoid negative effects towards the environment and health and helps to recycle material which the product is composed of For more detailed infor...

Страница 26: ...nadeemsq hto v Vawix rukax nawi plity budut funkcionirovat s maksimal noj otdahej i nailuhwimi rezul tatami opravdyvaq vse Vawi o idaniq S toj cel predlagaem Vam vnimatel no prohitat nastoq ee rukovod...

Страница 27: ...1156 1156 1156 LEKTRIHESKIE KONFORKI 145 1 0 kVt Obyhnaq konforka 1 5 kVt Bystraq konforka 180 1 5 kVt Obyhnaq konforka 2 0 kVt Bystraq konforka MO NOSTI LEMENTOV soprotivlenie poda 1 5 kVt soprotivl...

Страница 28: ...onnoj mebeli i dlq ravnomernogo raspredeleniq idkostej v kastr lqx pri pri gotvlenii pi i Smotri ris 18 50 C 3 A B 3 3 3 C D 2 st 2 1 Soedinenie rampy sootvetstvuet normam ISO 228 1 NASTROJKA NA RAZLI...

Страница 29: ...zetka zazemleniq funkcioniruet III Esli plita ukomplektovana setevym wnurom bez vilki to dlq podkl heniq mo no ispol zovat standartnu vilku Pri tom neobxodimo uhityvat sledu ee elto zelenyj provod dol...

Страница 30: ...spol zuetsq v tehenii dlitel nogo perioda vremeni rekomenduetsq slegka smazat irovoj smazkoj ee malirovannu poverxnost Izbegajte primeneniq abrazivnyx sredstv pri ohistke pover xnosti konforki RU KAK...

Страница 31: ...l hite lektrihesku spiral grilq Razmestite na rewetke prigotovlqemoe na grile kuwan e Ustanovite rewetku v duxovku v samoe verxnee polo enie Hut ni e rewetki postav te protiven Zakrojte dvercu duxovki...

Страница 32: ...duxovki s vozduxoduvkoj Temperatura duxovki reguliruetsq pri pomo i termoregul qtora Vo vsex polo eniqx za iskl heniem nulq proisxodit za iga nie krasnoj indikatornoj lampohki i lampy duxovki ZAMEHANI...

Страница 33: ...mo i standartnyx garantiru ix bezopasnost za imov V sluhae esli so vremenem kran podahi gaza budet okryvat sq s trudom rekomenduetsq vyzvat specialista Texniheskoj Slu by Dlq ohistki malirovannyx ili...

Страница 34: ...quer que V Exa obtenha deste aparelho o melhor rendimento justamente desejado no momento da compra do mesmo Com esta finalidade convidamo lo a seguir atentamente as instru es contidas neste manual Obv...

Страница 35: ...dura carga normal forno venti lado 55 8 55 8 Consumo na posi o de stand by em Watt rea til da superf cie de cozedura da pingadeira em cm2 1156 1156 1156 Dados t cnicos e caracter sticas DISCOS EL CTRI...

Страница 36: ...os acess rios do fog o Se assim n o for poder solicit la ao seu revendedor Se permitido pelas normas nacionais o tubo met lico r gido ou flex vel conforme s normas em vigor pode ser atarraxado directa...

Страница 37: ...lho tome cuidado para que os fios el ctricos das velas se existirem n o fiquem perto dos injectores para evitar que sejam esmagados pelos mesmos Instala o PT Queimador G20 20mbar G25 25mbar G30 28 30m...

Страница 38: ...determinados tipos de g s aconselha se a efectuar a opera o com o man pulo na po si o de m nimo chama pequena Para os fog es equipados com acendimento el ctrico nos quei madores do forno e do grelhado...

Страница 39: ...do forno s mbolo funcionamento do espeto com o grelhador aceso s mbolo accendimento resist ncia superior resist ncia infe rior cozedura convencional em forno est tico NOTA A l mpada piloto amarela ace...

Страница 40: ...RATOS Para abrir o compartimento destinado ao aquecimento de pratos levante a porta rebat vel com uma m o ver fig 16 Para fechar o compartimento basta empurrar a porta rebat vel para o respectivo aloj...

Страница 41: ...dos dados t cnicos aplicada no pr prio produto etiqueta com n mero de s rie Este s mbolo indica que o produto est classificado segundo as normas vigentes como equipamento el ctrico ou electr nico e qu...

Страница 42: ...ll 46 46 46 46 46 46 grill grill 47 47 4 47 4 new 47 Y 4 47 48 48 48 48 48 48 48 48 49 2002 96 EK 49 1935 2004 49 58 60 GR 2009 142 CE ex 90 396 2006 95 EK 73 23 2004 108 1935 2004 1275 2008 EOK 40 20...

Страница 43: ...1 2 1 GR 50x50 54x54 50x60 cm 85 0 cm 133 0 cm 133 3 cm 50 0 cm 96 0 cm 50 0 cm 85 0 cm 137 0 cm 137 3 cm 54 0 cm 100 0 cm 54 0 cm 85 0 cm 141 5 cm 142 3 cm 63 5 cm 106 0 cm 50 0 cm 39 5 cm 42 0 cm 3...

Страница 44: ...44 2 m h kW 1 2 st 2 1 100 C 20 cm NA TO O ETH ETE TA O APIA OPIZONTI H 18 50 C 3 A B 3 3 3 C D 2 2 1 LPG A ISO 228 1 4 C 43 5 7 mm GRILL 6 7 mm mm 6 grill GR...

Страница 45: ...45 G30 28 30mbar G31 37mbar grill 8 by pass by pass by pass 7 by pass by pass by pass 8 3 75 C H05RR F H05V2V2 F 2 H05RR F H05V2V2 F 2 2 ME 4 5 6 4 5 6 3 90 60 grill 10 90 60 grill GR...

Страница 46: ...KAY THPA OYPNOY A 9 B M 10 ANAMMA TOY KAY THPA GRILL GRILL Y PAEPIOY T 12 10 B M 10 IATA H A A EIA O 60 grill 90 IA KOYZINE grill K grill 10 A 10 1 POEI O OIH EI A A A K grill A XPH IMO OIOYNTAI OI E...

Страница 47: ...47 10 270 C 150 C 150 C 270 C GRILL 12 grill grill 1 2 6 8 10 15 12 5 20 4 5 8 12 10 2 15 grill grill grill GRILL grill grill grill grill 4 0 grill grill 10 4 New grill 0 grill 10 Y 4 0 grill 10 Y GR...

Страница 48: ...48 grill 0 grill grill 0 10 200 C a 13 grill grill b 13 14 H IMATO 15 210 100 0 0 16 1 2 B 1 2 17 3 4 5 B 1 6 GR...

Страница 49: ...49 2002 96 EK A A 2002 96 1935 2004 1935 2004 GR...

Страница 50: ...res prestaciones del mismo tal como usted esperaba en el momento de la compra Con este fin le invita a leer y seguir atentamente las instrucciones del presente manual aunque obviamente s lo deba tener...

Страница 51: ...do para cocci n carga normal ventilado en minutos 55 8 55 8 Consumo posici n stand by en watts Superficie til de la encimerabandeja grasera en cm2 1156 1156 1156 Caracter sticas t cnicas ES Cat ver pl...

Страница 52: ...punto de venta Si est permitido por las normas nacionales el tubo met lico r gido o flexible conforme a las normas vigentes puede enroscarse directamente en la rosca de la rampa interponiendo una junt...

Страница 53: ...aire es escaso la llama tiene puntas amarillas y puede producir holl n REGULACION DEL M NIMO QUEMADORES DE LA ENCI MERA En caso de que la cocina deba funcionar con gas l quido B P el by pass de las es...

Страница 54: ...ncendido el ctrico sea dificultoso para determina dos tipos de gas se aconseja efectuar la operaci n con el mando en la posici n de m nimo llama peque a En las cocinas con encendido el ctrico en los q...

Страница 55: ...r controlados por un selector y regulados por un termostato partiendo de la posici n 0 apagado y girando el mando en sentido horario se encuen tran las siguientes posiciones simbolo encendido de la l...

Страница 56: ...procedimiento de desenganche en orden y sentido inverso insertar las dos bisagras en los respectivos alojamientos y abrir por completo la puerta 5 girar las dos palancas B para situarlas nuevamente e...

Страница 57: ...vo aparato de tipo equivalente El usuario ser responsable de la entrega del aparato al final de su vida til a los centros de recogida correspondientes so pena de las sanciones previstas por la legisla...

Страница 58: ...1 230 V BIFASE BIPHASE TWO PHASE DVUXFAZNYJ BIF SICO BIFASICO 400 V MONOFASE NEUTRO MONOPHASE NEUTRE SINGLE PHASE NEU TRAL ODNOFAZNYJ NEJTRAL MONOF SICO NEUTRO MONO MONOFASICO NEUTRO Sez cavo Section...

Страница 59: ...PARA TERMOPAR TERMOPAR B CANDELA D ACCENSIONE BOUGIE D ALLUMAGE SPARK PLUG SVEHA ZA IGANIQ VELA DE IGNI O BUJ A DE ENCENDIDO 5 9 10 12 13 A TERMOCOPPIA THERMOCOUPLE THERMOCOUPLE TERMOPARA TERMOPAR TER...

Страница 60: ...60 Figure Figures Figures Risunki Figuras Figuras Ed 11 09 2012 33422801 15 45 60 30 14 16 17 15 0 15 30 45 60 75 90 105 120 18 POSITION 1 POSITION 2 B...

Отзывы: