Signal-10
Operation Principles
37
www.bolid.com
OPERATING MODES
The Signal-10 device offers the following modes:
Pre-Operation Mode
Operation Mode
Power Failure Mode
Output Circuit Failure Mode
Master Key Programming Mode
User Key Programming Mode
Self-Diagnostic Mode
Device Failure Mode
For description of READY LED operation in different modes of the Signal-10 device, please refer
to Table 6.
Table 6. READY LED Behavior in Different Signal-10 Operating Modes
№
Operating mode
LED Behavior
1
Pre-Operation Mode
OFF
2
Operation Mode
Lit with green
3
Master/User Key Programming Mode
Double flashes with green every second
4
Power Failure Mode
Flashes yellow once per second
5
Self-Diagnostic Mode
Flashes red twice per second
6
Device Failure Mode
Flashes red four times per second
7
Output Circuit Failure Mode
Flashes red once per second
Pre-Operation Mode
When supply voltage is applied to power terminals, the device activates and switches to the Pre-
Operation Mode. The device power-up time doesn’t exceed 3 seconds provided that 11V or higher is
available at least at one power input.
Operation Mode
After the Pre-Operation Mode the device switches to the Operation Mode. In the Operation Mode the
device provides its main functions, those are alarm loop monitoring, fire alarming, trouble monitoring,
built-in relay performance monitoring and control. When used together with the Orion network control-
ler, the Signal-10 also communicates data with the network controller.
Please note, that the device sounds with a melody and the READY LED is switched on with green to
enable user to easily recognize that the device has successfully switched to the Operation Mode.
Содержание Signal-10
Страница 1: ...Orion ISS Intrusion and Fire Alarm Panel Signal 10 User s Manual ...
Страница 5: ...Signal 10 General 5 www bolid com GENERAL ...
Страница 8: ...Orion ISS www bolid com 8 ...
Страница 9: ...Signal 10 Specifications 9 www bolid com SPECIFICATIONS ...
Страница 13: ...Signal 10 Operation Principles 13 www bolid com OPERATION PRINCIPLES ...
Страница 59: ...Signal 10 Installation 59 www bolid com INSTALLATION ...
Страница 61: ...Signal 10 Installation 61 www bolid com Figure 2 Signal 10 Overall and Mounting Dimensions ...
Страница 68: ...Orion ISS www bolid com 68 Figure 10 Measuring Alarm Loop Resistances by Means of UProg ...
Страница 69: ...Signal 10 Installation 69 www bolid com ...
Страница 70: ...Orion ISS www bolid com 70 PROGRAMMING ...
Страница 90: ...Orion ISS www bolid com 90 MAINTENANCE ...
Страница 95: ...Signal 10 Annex Current Consumption Estimation 95 www bolid com ...
Страница 96: ......