SAFETY IN STRUC TIONS FOR OP ER ATING AND SER VICE PER SON NEL
Op er a tors and ser vice per son nel should al ways wear safety glasses. Op er a tors shall not en ter ar eas in tended
for ser vice ac cess only. Only ex pe ri enced ser vice per son nel should en ter such ar eas, and only af ter tak ing the
pre lim i nary pre cau tions de scribed in para graphs 1 through 6 be low.
DANGER
Po ten tially le thal volt ages may ex ist within this sys tem, even with the main power switched off. Ser vice
should only be at tempted by qual i fied per son nel. Fail ure to ob serve all safety pre cau tions can re sult in
per sonal in jury.
Ob serve the pre cau tions de scribed be low when ser vic ing this sys tem, es pe cially when ser vic ing com po nents
where high volt ages might be pres ent.
1
Be fore ser vic ing or op er at ing this equip ment, read all the com po nent man u als sup plied with the sys tem,
pay ing spe cial at ten tion to safety in struc tions.
2
Post HIGH VOLT AGE WARNING signs in con spic u ous lo ca tions within the ser vice area.
3
Re move rings, watches, brace lets, and any other metal jew elry be fore work ing around high volt age.
4
DO NOT WORK ALONE!
5
Be sure that all equip ment is con nected to a power re cep ta cle hav ing the cor rect po lar ity and ground ing,
as pre scribed by the lo cal elec tri cal codes. Re fer to the power sup ply por tion of the doc u men ta tion to de -
ter mine the proper elec tri cal ground for high-volt age com po nents.
6
Be fore ser vic ing any high-volt age com po nent, switch off the elec tri cal power at the com po nent’s main
power switch. This switch should have a lock out fea ture. Lock the power off and keep the key with you
while you are work ing on the equip ment.
7
Cer tain elec tri cal parts (e.g., elec tro lytic ca pac i tors) hold a le thal volt age even af ter the power is switched
off. Be fore en ter ing any ser vice area, use a ground ing hook to short out such parts. Be sure that these
parts are dis charged be fore start ing any re pairs.
8
DO NOT touch high-volt age leads un less power is off and a ground ing hook is con nected to the parts to
be ser viced.
9
The high-volt age com po nents of the sys tem should be equipped with elec tri cal in ter locks to pro tect per -
son nel from in jury. DO NOT AT TEMPT TO DE FEAT, OVER RIDE, OR BY PASS THESE PRO TEC -
TIVE DE VICES!
10
Never leave loose ends on high-volt age con nec tions.
11
Ob serve the fol low ing warn ing if the sys tem em ploys Ra dio Fre quency (RF) power.
DANGER
RF ra di a tion-even at mod est power lev els-can cause se ri ous in jury. If any of the RF com po nents (e.g.,
the RF power sup ply, the RF match ing net work, or the RF elec trodes or shield ing in side the prod uct
cham ber) are moved or changed in any way, the RF en ergy may be ra di ated out side the equip ment.
Mon i tor the equip ment to as sure that ex ter nal RF ra di a tion is be low the lev els pre scribed by any and
all ap pli ca ble safety codes.