13
BA-077/1EN M6X.20XX
3 - How to operate the machine
3.1 - Description of operator panels
3.1.1) Designation of operating elements
•
(E1)
... Main switch= Emergency off switch
•
(E2)
... Mode switch
•
(E3)
... Start button
•
(E4)
... Hold down clamp switch
•
(E5)
... Control light for horizontal drilling
•
(E6)
... Control light for vertical drilling
3.1.2) Mode switch
(E2)
• Key switch version
Pos. OFF
Control lights are not lit
- The machine will not operate
Pos. Settings
Control light
(E5)
or
(E6)
are lit
- Drill head movement is possible
- Drilling is not possible
Pos. Operation
Control light
(E5)
or
(E6)
are lit
- Drilling and the fitting insertion can be carried out
3.1.3) Start button
(E3)
• Pressing the start button will carry out the currently selected work process
(e.g.: setup, vertical drilling, horizontal drilling and fittings insertion)
• When you release the start button, the work process is cancelled and the vertical or
horizontal drilling unit returns to the starting position. The hold down clamps remain
extended.
3.1.4) Hold down clamp switch (E4)
Pos. Clamps off and/or released
(Hold down clamps are not extended and/or are released when they are
already extended)
Pos. Clamps on
(When you push the start button, the hold down clamps are extended)