Where:
Parameter
Description
Mode
Dynamic power management activation / deactivation in ‘continuous’ mode:
•
0x00: Off;
•
0x01: Up, only increase power by power step every time step;
•
0x02: Up / Down, increase power and then decrease it by power step every
time step.
Power Step
Power step:
•
0x0
1 … 0x05 for power step in dB (1
… 5 dB);
•
0x81 … 0xB2 for power step in mW x 10 (10 …
500 mW).
Time Step
Time step:
•
Decimal
1 … 99 for time in ms x 100 (0.1
… 9.9 seconds).
The changed Dynamic Power Management parameters become
effective only after a reset of the
BLUEBOX
. Reset the
BLUEBOX
using the ‘Reset Device’ command or via a hardware reset.
3.3
Device Status
The information about the current status of the
BLUEBOX
shall be read with the
‘Read Device Status’ command as described in protocol technical manuals where
the status bytes 1 and 2 have the following meaning.
Status Byte
Description
Status Byte 1
Byte whose bits have the following meaning:
•
Bit 7: Not used
•
Bit 6: Not used;
•
Bit 5: RF status (0=off, 1=on)
•
Bit 4: ‘Continuous’ mode (1=enabled)
•
Bit 3: Not used
•
Bit 2: Not used
•
Bit 1: Output 2 status (1=activated)
•
Bit 0: Output 1 status (1=activated)
Status Byte 2
Byte whose bits have the following meaning:
•
Bit 7: Not used
•
Bit 6: Not used
•
Bit 5: Not used
•
Bit 4: Not used
Содержание IDTRONIC UHF Advant 5238U-PN-C
Страница 1: ...BLUEBOX Advant Profinet Page 1 of 71 UHF RFID System BLUEBOX Advant 5238U PN C Profinet ...
Страница 38: ...BLUEBOX Advant Profinet Page 38 of 71 7 Mechanical Drawings Dimensions in mm ...
Страница 67: ...BLUEBOX Advant Profinet Page 67 of 71 5 On the next screen choose Advanced Options ...
Страница 68: ...BLUEBOX Advant Profinet Page 68 of 71 6 Then click on Startup Settings ...
Страница 71: ...BLUEBOX Advant Profinet Page 71 of 71 ...