BLUEBOX Advant Profinet
Page 10 of 71
triggered with the activation of the other input but, the activation of the
‘continuous’ mode could also be extended with the ‘extension time’ (to be
set in a range of 0 … 99 seconds or 0 ... 99 minutes, default value 0
seconds). The crossing of the gate is managed with a maximum crossing
‘gate time’ (to be set in a range of 0 … 99 seconds or 0 ... 99 minutes,
default value 0 seconds)
which deactivates the ‘continuous’ mode in case
of no successful crossing of the gate within this time. Only with a
successful crossing of the gate data (tag ID and gate crossing direction
and optionally tag type and reading antenna) are save in buffer and FIFO.
The
BLUEBOX
allows the execution of ‘on request’ functions. During the
execution of these functions, the ‘continuous’ identification activity will be
suspended temporarily; the involved commands are relative to device
configuration and tag read/write specific activities.
If not required, the
‘continuous’ identification activity can be disabled through a
flag defined in the general parameters. In this case, the
BLUEBOX
will only
execute the ‘on request’ commands already defined above.
Two ‘test’ mode
are also defined:
•
‘RF Reading’ test: in ‘continuous’ mode allows the user to easily and
quickly test the read range of the device with fast beeping (100ms) the
buzzer (the buzzer must be connected to output 2) for every identified
tag. This ‘test’ mode is
stored in non volatile memory and its status is kept
at every device restart and until it is disabled.
•
‘RF Power’ test: allows the user to easily and quickly test the minimum RF
output power needed to read a tag in a fixed position. The device sweeps
from the minimum RF output power to maximum RF output power or until
it finds a tag, increasing the RF power of 1 dB every 500ms with fixed Q
selection algorithm and Q=0. It is an ‘on request’ function which
temporarily suspends the ‘continuous’ mode.
3.1
General Parameters
Hereinafter the configurable general parameter of the
BLUEBOX
.
Parameter
Description
Range
Default
Filter Time
Reading and tag queue management filter time.
0 setting is internally overwritten with 1 second.
0 … 99 seconds
0 … 99 minutes
1 sec
Buzzer
Management
Buzzer management on ‘new tag’ event.
Disabled,
enabled
Enabled
Output 1
Management
Output 1 management on ‘new tag’ event.
Disabled,
enabled
Disabled
Содержание IDTRONIC UHF Advant 5238U-PN-C
Страница 1: ...BLUEBOX Advant Profinet Page 1 of 71 UHF RFID System BLUEBOX Advant 5238U PN C Profinet ...
Страница 38: ...BLUEBOX Advant Profinet Page 38 of 71 7 Mechanical Drawings Dimensions in mm ...
Страница 67: ...BLUEBOX Advant Profinet Page 67 of 71 5 On the next screen choose Advanced Options ...
Страница 68: ...BLUEBOX Advant Profinet Page 68 of 71 6 Then click on Startup Settings ...
Страница 71: ...BLUEBOX Advant Profinet Page 71 of 71 ...