3
Operating Features
In ‘continuous’ mode the
BLUEBOX
is characterized by the coexistence of 2
‘parallel’ and asynchronous activities: the tag
identification (inventory) and the
communication with the ‘host’ system. The ‘continuous’ identification activity
interacts with the communication activity through a buffer that contains the code
of the last identified tags or that is empty indicating the absence of tags. Due to
synchronization and filtering reasons, the buffer is handled for each identified
tag by a parameter defined as ‘hold time’ (same as ‘filter time’ defined below,
to be set in the range of 0 … 99 seconds or 0 ... 99 minutes, default v
alue 1
second) and allows to extend ‘artificially’ the presence of the tag after it leaves
the antenna’s influence area; this behavior is observable looking at the yellow
led status that is ‘on’ indicating the presence of tags and also through the
activat
ion of the relay nr 1 (if its ‘automatic’ management is enabled by the flag
defined in the general parameters). Through the command ‘data request’ it is
possible to get the data contained in the buffer (tag/s ID/s and optionally tag/s
type/s, reading anten
na and gate crossing direction in ‘gate mode’); the
indication of the reading antenna can be enabled/disabled through a flag defined
in the general parameters.
The
BLUEBOX
handles also a 1000 elements FIFO queue which is combined with
the ‘filter time’ general parameter (to be set in a range of 0 … 99 seconds or 0
... 99 minutes, default value 1 second) that prevents the queue saturation in
case of a tag ‘continuous’ presence. When a tag is identified, the
BLUEBOX
verifies if it belongs to the list of read tags. If the tag do not belong to the list
(it is defined as ‘new’), its code will be inserted in the queue, a filter time
assigned to the tag will be started and the buzzer will be activated for 0.5
seconds (if its ‘automatic’ management is enabled by th
e flag defined in the
general parameters). Otherwise (the tag belong to the list of read tags), the
BLUEBOX
verifies if the relative filter time is expired. In this case (the filter time
is expired), the tag is defined as ‘new’ and will be processed as des
cribed above,
otherwise only the relative filter time will be rearmed. Through the command
‘queue data request’ and the relative ‘ack’, it is possible to get the data contained
in the queue (tag ID and optionally tag type, reading antenna and gate crossing
direction in ‘gate mode’) and unload it; the indication of the reading antenna can
be enabled/disabled through a flag defined in the general parameters.
Two subsets of the ‘continuous’ mode are also defined:
•
‘Trigger’ mode: the activation and deactivation
of the ‘continuous’ mode is
triggered with inputs. The trigger could be level sensitive or edge sensitive
depending on the ‘extension time’ setting (to be set in a range of 0 … 99
seconds or 0 ... 99 minutes, default value 0 seconds).
•
‘Gate’ mode: the activation of the ‘continuous’ mode is triggered with the
activation of an input. The deactivation of the ‘continuous’ mode is
Содержание IDTRONIC UHF Advant 5238U-PN-C
Страница 1: ...BLUEBOX Advant Profinet Page 1 of 71 UHF RFID System BLUEBOX Advant 5238U PN C Profinet ...
Страница 38: ...BLUEBOX Advant Profinet Page 38 of 71 7 Mechanical Drawings Dimensions in mm ...
Страница 67: ...BLUEBOX Advant Profinet Page 67 of 71 5 On the next screen choose Advanced Options ...
Страница 68: ...BLUEBOX Advant Profinet Page 68 of 71 6 Then click on Startup Settings ...
Страница 71: ...BLUEBOX Advant Profinet Page 71 of 71 ...