BLUEBOX Advant Profinet
Page 13 of 71
The IP address, subnet mask and gateway are not writeable
because they are set by an IO Controller, IO Supervisor or
Engineering System through the DCP protocol.
3.2.2
ProfiNet
Hereinafter the configurable ProfiNet parameters of the
BLUEBOX
.
Parameter
Description
Range
Default
ProfiNet
Station Name
The station name of the device in the ProfiNet
network.
Variable string
0…240 bytes
ProfiNet Buffer
Length
The ProfiNet IN/OUT buffer size in bytes.
8, 12, 16, 20,
32, 64
16
The ProfiNet parameters are stored in configuration page nr. 0x03 and 0xC0 and
are managed through the ‘Read Configuration Parameters’ and ‘Write
Configuration Parameters’ commands as described in protocol technical
manuals.
The parameters 1…7 fields with default values of page 0x03 are
1
2
3
4
5
6
7
0x7E
Buffer
Length
0x00
0x00
0x00
0x00
0x00
0x7E
0x02
0x00
0x00
0x00
0x00
0x00
Where:
Parameter
Description
ProfiNet Bufer
Length
The ProfiNet IN/OUT buffer size in bytes:
•
0x00: 8 bytes
•
0x01: 12 bytes
•
0x02: 16 bytes
•
0x03: 20 bytes
•
0x04: 32 bytes
•
0x05: 64 bytes
The parameters 1…240 fields with default values of page 0xC0 are
1
2
…
…
…
239
240
Содержание IDTRONIC UHF Advant 5238U-PN-C
Страница 1: ...BLUEBOX Advant Profinet Page 1 of 71 UHF RFID System BLUEBOX Advant 5238U PN C Profinet ...
Страница 38: ...BLUEBOX Advant Profinet Page 38 of 71 7 Mechanical Drawings Dimensions in mm ...
Страница 67: ...BLUEBOX Advant Profinet Page 67 of 71 5 On the next screen choose Advanced Options ...
Страница 68: ...BLUEBOX Advant Profinet Page 68 of 71 6 Then click on Startup Settings ...
Страница 71: ...BLUEBOX Advant Profinet Page 71 of 71 ...