Regions of Operation
The
BLUEBOX
reader has been designed to work in various regions with
differing frequency requirements. This document covers operation in North
America and Europe.
In each region, the reader is not locked to only operate in the
specific frequencies listed in the respective frequency plan tables
shown in next paragraphs. The user is responsible to correctly use
the
BLUEBOX
in the relative region.
A.1.
Operation in North America
The FCC specifies frequency hopping across the North American spectrum
allocated to UHF RFID (902
−
928 MHz, with hopping occurring between
902.75
−
927.25 MHz in 500 KHz steps). This specification states that no listen-
before-talk is performed, the maximum continuous transmit time on a channel
is 0.4 seconds.
RF Channel
Frequency [MHz]
1
902.75
2
903.25
3
903.75
…
…
49
926.75
50
927.25
A.2.
Operation in Europe
For European operation, the
BLUEBOX
reader supports the frequency plan listed
in the table below and is compliant with the ratified ETSI EN 302-208
specification V.1.4.1. This specification states that no listen-before-talk is
performed, the maximum continuous transmit time on a channel is four seconds,
and the reader enforces the 100 ms off time before reusing the same channel.
In some applications (i.e. conveyor systems) it may be necessary for
interrogators to transmit while tags are not present. To accommodate such
Содержание IDTRONIC UHF Advant 5238U-PN-C
Страница 1: ...BLUEBOX Advant Profinet Page 1 of 71 UHF RFID System BLUEBOX Advant 5238U PN C Profinet ...
Страница 38: ...BLUEBOX Advant Profinet Page 38 of 71 7 Mechanical Drawings Dimensions in mm ...
Страница 67: ...BLUEBOX Advant Profinet Page 67 of 71 5 On the next screen choose Advanced Options ...
Страница 68: ...BLUEBOX Advant Profinet Page 68 of 71 6 Then click on Startup Settings ...
Страница 71: ...BLUEBOX Advant Profinet Page 71 of 71 ...