BLUEBOX Advant Profinet
Page 14 of 71
ProfiNet
Station
Name 1
ProfiNet
Station
Name 2
…
…
…
ProfiNet
Station
Name 239
ProfiNet
Station
Name 240
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Where:
Parameter
Description
ProfiBus
Station Name
The ProfiNet Sation Name is a null terminated variable string with max length of 240
bytes.
The changed ProfiNet parameters become effective only after a
reset of the
BLUEBOX
. Reset the
BLUEBOX
using the ‘Reset
Device’ command or via a hardware reset.
The station name is not writeable because it is set by an IO
Controller, IO Supervisor or Engineering System through the DCP
protocol.
3.2.1
Input/Output
Hereinafter the configurable Input/Output parameters of the
BLUEBOX
.
Parameter
Description
Range
Default
Input 1 Mode
Input 1 activation / deactivation mode of the
‘continuous’ mode in ‘trigger’ mode.
0, 1, 2
1
Input 2 Mode
Input 2 activation / deactivation mode of the
‘continuous’ mode in ‘trigger’ mode.
0, 1, 2
0
Extension
Time
‘Continuous’ mode activation/deactivation
management with inputs extension time.
1.
In ‘trigger’ mode, if =0 the trigger is
level sensitive, otherwise it is edge
sensitive and this time defines the
‘continuous’ mode activation time
extension.
2.
In ‘gate’ mode it defines the
‘continuous’ mode activation time
extension after the crossing of the
gate.
0 … 99
seconds
0 … 99
minutes
0
Содержание IDTRONIC UHF Advant 5238U-PN-C
Страница 1: ...BLUEBOX Advant Profinet Page 1 of 71 UHF RFID System BLUEBOX Advant 5238U PN C Profinet ...
Страница 38: ...BLUEBOX Advant Profinet Page 38 of 71 7 Mechanical Drawings Dimensions in mm ...
Страница 67: ...BLUEBOX Advant Profinet Page 67 of 71 5 On the next screen choose Advanced Options ...
Страница 68: ...BLUEBOX Advant Profinet Page 68 of 71 6 Then click on Startup Settings ...
Страница 71: ...BLUEBOX Advant Profinet Page 71 of 71 ...