BLUEBOX Advant Profinet
Page 16 of 71
Parameter
Description
Input1 Mode
Input 1 activation / deactivation mode of the ‘continuous’ mode in ‘trigger’ mode:
•
0x00: Disabled
•
0x01: ON -> Activate antennas; OFF -> Deactivate antennas
•
0x02: OFF -> Activate antennas; ON -> Deactivate antennas
Input2 Mode
Input 2 activation / deactivation mode of the ‘continuous’ mode in ‘trigger’ mode:
•
0x00: Disabled
•
0x01: ON -> Activate antennas; OFF -> Deactivate antennas
•
0x02: OFF -> Activate antennas; ON -> Deactivate antennas
Extension
Time
‘Continuous’ mode activation/deactivation management with inputs extension time.
•
In ‘trigger’ mode, if =0 the trigger is level sensitive, otherwise it is edge
sensitive and this time defines the ‘continuous’ mode activation time
extension.
•
In ‘gate’ mode it defines the ‘continuous’ mode activation time extension
after the crossing of the gate.
And the values allowed are:
•
Decimal 0 … 99 for time in seconds (0 … 99 seconds);
•
Decimal 100 … 199 for time in minutes (0 … 99
minutes).
Gate Time
The maximum gate crossing time. If =0 the ‘gate’ mode is disabled, otherwise it is
the maximum gate crossing time:
•
Decimal 0 … 99 for time in seconds (0 … 99 seconds);
•
Decimal 100 … 199 for time in minutes (0 … 99 minutes).
Debounce
Time
The inputs anti-bounce time. If =0 a minimum bounce time of 50ms is internally set.
•
Decimal 0 … 99 for time in mseconds (0 … 990 mseconds)
•
Decimal 100 … 199 for time in seconds (0.0 … 9.9 seconds)
The changed Input/Output parameters become effective only after
a reset of the
BLUEBOX
. Reset the
BLUEBOX
using the ‘Reset
Device’ command or via a hardware reset.
3.2.2
RF and EPC C1G2 (Class-1 Generation-2)
Hereinafter the configurable RF parameters of the
BLUEBOX
.
Parameter
Description
Range
Default
RF Region
RF geographical region.
Europe (ETSI
compliant
region), North
America (FCC
compliant
region)
Europe (ETSI
compliant
region)
Содержание IDTRONIC UHF Advant 5238U-PN-C
Страница 1: ...BLUEBOX Advant Profinet Page 1 of 71 UHF RFID System BLUEBOX Advant 5238U PN C Profinet ...
Страница 38: ...BLUEBOX Advant Profinet Page 38 of 71 7 Mechanical Drawings Dimensions in mm ...
Страница 67: ...BLUEBOX Advant Profinet Page 67 of 71 5 On the next screen choose Advanced Options ...
Страница 68: ...BLUEBOX Advant Profinet Page 68 of 71 6 Then click on Startup Settings ...
Страница 71: ...BLUEBOX Advant Profinet Page 71 of 71 ...