BLUEBOX Advant Profinet
Page 15 of 71
Parameter
Description
Range
Default
Gate Time
Maximum gate crossing time. If =0 the ‘gate’
mode is disabled, otherwise it is the maximum
gate crossing time.
0 … 99
seconds
0 … 99
minutes
0
Debounce
Time
The inputs debounce time. If =0 a minimum
bounce time of 50ms is internally set.
0.00 … 0.99
seconds
0.0 … 9.9
seconds
0
Where the input mode range means
•
0: Disabled;
•
1: ON -> Activate antennas; OFF -> Deactivate antennas;
•
2: OFF -> Activate antennas; ON -> Deactivate antennas;
The input 1 and 2 modes combination allowed are
Input 1 Mode
Input 2 Mode
ON -> Activate antennas; OFF -> Deactivate
antennas
Disabled
OFF -> Activate antennas; ON -> Deactivate
antennas
Disabled
Disabled
ON -> Activate antennas; OFF -> Deactivate
antennas
Disabled
OFF -> Activate antenna 1 & 2; ON ->
Deactivate antenna 1 & 2
The Input/Output parameters are stored in configuration page nr. 0x05 and are
managed through the ‘Read Configuration Parameters’ and ‘Write Configuration
Parameters’ commands as
described in protocol technical manuals where the
parameters 1…7 fields with default values are:
1
2
3
4
5
6
7
Input1
Mode
Input2
Mode
Extension
Time
Gate Time
Debounce
Time
0x00
0x00
0x01
0x00
0x00
0x00
0x00
0x00
0x00
Where:
Содержание IDTRONIC UHF Advant 5238U-PN-C
Страница 1: ...BLUEBOX Advant Profinet Page 1 of 71 UHF RFID System BLUEBOX Advant 5238U PN C Profinet ...
Страница 38: ...BLUEBOX Advant Profinet Page 38 of 71 7 Mechanical Drawings Dimensions in mm ...
Страница 67: ...BLUEBOX Advant Profinet Page 67 of 71 5 On the next screen choose Advanced Options ...
Страница 68: ...BLUEBOX Advant Profinet Page 68 of 71 6 Then click on Startup Settings ...
Страница 71: ...BLUEBOX Advant Profinet Page 71 of 71 ...