DATE PRINTED: 2/8/05 Revision Date: 04/15/04
OM-2205 Page 26
APPENDIX ‘B’ (CONVERSION KITS)
“ This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of the authorities having jurisdiction. If the information
in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life. The qualified service agency is responsible for the
proper installation of the kit. The installation is not complete until the operation of the converted appliance is
checked as specified in the instruction manual supplied with the kit.” Before performing this or any service
procedure, make sure that the gas supply to the unit and the electrical supply are shut off.
1. Main Burner orifice.
2. Pilot Orifice
3.
Valve Kit.
4.
Conversion Sticker
CONVERSION KIT CONTENTS
To convert to an alternate fuel, follow these steps:
1. Open the front viewing door.
2. Remove the log set and brick panels.
3. Remove the log support plate screws.
4. Remove the burner assembly.
5. Using a 1/2” socket, unscrew the main burner orifice
and replace with alternate gas orifice.
6. Carefully unscrew the pilot assembly (2 screws) and re-
move the pilot orifice and replace with alternate pilot ori-
fice.
7. Convert the gas valve. See the separate gas valve
manufacturers instructions supplied in the kit.
8. Fill out conversion sticker supplied in conversion kit.
The model 2205 is designed to burn either Natural Gas or
Propane (LP) Fuel. Each heater leaves the factory equipped
for one specific fuel but it is a simple operation to convert the
heater to an alternate fuel in the field. The original fuel type is
marked on the rating label:
NATURAL GAS PROPANE
LEAK TESTING:
CAUTION: DO NOT TEST FOR LEAKS WITH AN OPEN FLAME.
♦
With the main burner “ON”, test the new pressure regulator using a soap solution
♦
Check all fittings for leaks using the soap solution.
FUEL CONVERSION LABEL:
♦
Fill out and attach the fuel conversion label provided in the kit.
IMPORTANT
: YOU CHANGED THE FUEL WHICH MEANS THE AERATION WILL REQUIRE ADJUSTMENT
AERATION ADJUSTMENT
See page 14 for instructions on adjusting the aeration.
ALLOW THE UNIT TO BURN FOR AT LEAST 15 MINUTES TO CHECK THE FLAME PICTURE.
♦
If you have converted from Natural gas to Propane you will have to INCREASE the aeration opening as propane requires
more primary air to burn correctly.
♦
If you have changed from Propane to Natural gas you may have to REDUCE the aeration opening as Natural gas re-
quires less primary air to burn correctly.