DATE PRINTED: 2/8/05 Revision Date: 04/15/04
OM-2205 Page 11
The fireplace flue damper can be fully blocked open or removed
for installation of the gas fireplace insert.
The fireplace and chimney must be clean and in good working
order and constructed of non-combustible materials. Chimney
cleanouts must fit properly.
INSTALLATION
(
DIRECT VENT
)
VENTING CHART
“WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury”.
30 FT MAXIMUM
VERTICAL RISE,
MINIMUM 8 FT
Intake
Connector
Exhaust
Connector
The model 2205 is only certified for vertical terminations.
VENT TERMINAL CLEARANCES
2FT MAXIMUM
HORIZONTAL RUN
This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.
Refractory material, glass doors, screen rails, screen mesh and
log grates can be removed from the fireplace before installing
the gas fireplace insert. Smoke shelves, shields and baffles
may be removed if attached by mechanical fasteners. Trim
panels or surrounds shall not seal ventilation openings in the
fireplace.
Consult local codes for minimum vent cap height above the roof
(X), vent must be a minimum of 2’ from any wall.