DATE PRINTED: 2/8/05 Revision Date: 04/15/04
OM-2205 Page 12
ONLY PERSONS LICENSED TO WORK WITH GAS PIPING MAY MAKE THE NECESSARY GAS CONNECTION TO
THIS APPLIANCE. YOU ARE NOW READY TO HOOK UP THE GAS SUPPLY. BE SURE GAS PLUMBING
INSTRUCTIONS AND ALL PROVINCIAL AND LOCAL CODES ARE CAREFULLY FOLLOWED. USE APPROVED
FLEXIBLE GAS CONNECTIONS OR RIGID PIPING, DEPENDING ON PROVINCIAL AND LOCAL CODES, TO
ATTACH BURNER TO GAS SUPPLY. BE SURE TO USE PROPER SIZE GAS SUPPLY LINE. CAREFULLY CHECK
ALL CONNECTIONS WITH A SOAP AND WATER SOLUTION FOR GAS LEAKS. EACH INSTALLATION MUST
CONFORM TO ALL LOCAL, PROVINCIAL AND NATIONAL CODES. REFER TO THE NATIONAL FUEL GAS CODE,
LOCAL ZONING AND CODE AUTHORITIES FOR DETAILS ON INSTALLATION REQUIREMENTS.
EXISTING GAS SUPPLY
Before interrupting the existing gas supply it is recommended that the following be checked.
♦
Shut down all gas appliances and carry out a pressure test to insure there are no existing leaks on the system.
♦
Before connecting the appliance to the gas supply line, double check that the appliance you have purchased is
designed for the gas type you are using. The gas type markings are located on the certification label and also
on the appliance’s gas valve.
♦
Check the gas pressure to insure you will be able to supply the minimum inlet pressure for the appliance (see
page 12).
♦
Check your pipe sizing to insure sufficient volume will be supplied to the appliance.
Provide adequate clearance for proper installation and checking of the gas connections.
Have your gas supplier or a qualified gas fitter run a gas supply line into the gas fireplace. The line must be
properly sized and fitted according to the installation codes. Up stream of the appliance supply connection, the
fitter shall provide an easily accessible manual shut-off valve.
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). The appliance must be isolated
from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the
gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa). Failure to do so will damage the
appliance’s gas valve. Such damage is not covered by the manufacturer’s warranty.
Check for proper gas supply pressure by loosening the set-screw on inlet pressure tap (marked
IN
) on the gas
valve with a small flat tip or Phillips screw driver and placing a test gauge on the tap.
The minimum permissible gas supply pressure is 5.0 in. w.c. (1.24 kPa) for natural gas and 12.1 in. w.c. (3.00 kPa)
for propane. Maximum gas supply pressure should never exceed 14.0 in. w.c. (3.48 kPa) or 1/2 psi. for both
natural gas and propane.
BE SURE TO TIGHTEN THE PRESSURE TAP SET-SCREW AFTER CHECKING THE PRESSURE. CHECK
ALL GAS CONNECTIONS FOR GAS LEAKS.
GAS SUPPLY INSTALLATION
INSTALLATION
(
GAS SUPPLY
)
Содержание 2205
Страница 9: ...DATE PRINTED 2 8 05 Revision Date 04 15 04 OM 2205 Page 9 CLEARANCES TO COMBUSTIBLES ...
Страница 16: ...DATE PRINTED 2 8 05 Revision Date 04 15 04 OM 2205 Page 16 SHROUD KIT GRILL ROD KIT INSTALLTION ...
Страница 31: ...DATE PRINTED 2 8 05 Revision Date 04 15 04 OM 2205 Page 31 NOTES ...