DATE PRINTED: 2/8/05 Revision Date: 04/15/04
OM-2205 Page 19
DO NOT:
Use tools to operate controls, only use your hand to push in and turn the controls.
DO NOT:
Try to repair the appliance. Call a qualified service technician.
DO NOT:
Use this appliance if any part has been under water. Immediately call a qualified service technician to inspect
the appliance and replace any part of the gas control system which has been under water.
DO NOT:
Use this appliance if you smell gas.
WHAT TO DO IF YOU SMELL GAS:
♦
OPEN WINDOWS.
♦
DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE THE PHONE IN YOUR BUILDING.
♦
EXTINGUISH ANY OPEN FLAME.
♦
IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE AND FOLLOW THE GAS SUPPLIER’S IN-
STRUCTIONS.
OPERATING INSTRUCTIONS—PRE-START UP CHECK LIST
START-UP PROCEDURE
1. Set the thermostat, if present, to the lowest level. Switch
burner switch to
OFF.
Set the flame adjustment knob to the
HI
position. Press slightly and turn the control knob
clockwise
to the
OFF
position and wait 5 minutes; thus
allowing any gases to escape which may have accumulated
in the combustion chamber. IF YOU SMELL GAS
STOP!
FOLLOW INSTRUCTIONS ON PAGE 19.
(
Note:
LP gases do not vent upward). Then follow steps 2
and 3 to establish pilot.
2. Press slightly and turn control knob counterclockwise
to
PILOT
position; depress control knob and light pilot by
repeatedly pressing the sparker. Venting of air may take
place at the pilot prior to the flow of fuel gases. Once flame
is established, hold knob depressed for approximately 60
sec.
3. Release knob. If the pilot will not light or the control knob
does not pop up when released, turn the control knob to
OFF
and call your service technician or gas supplier. If the
pilot should go out, turn the control knob to
OFF
position and
repeat steps 1, 2 and 3.
Note:
this will allow reset of INTERLOCK for proper lighting
of pilot.
Also the Honeywell valve is equipped with a safety lockout,
once in the off position you must wait until the thermopile has
cooled down before attempting to light the pilot
(approximately 3 minutes).
4. Press and turn control knob counterclockwise
to
ON
position.
5. Turn flame and heat adjustment knob to the desired comfort
level from
HI
GH to
LO
W.
6. Turn thermostat to the desired comfort level or turn ON/OFF
switch to the ON position.
♦
NOTE: When first fired, the unit will produce an odor. This is
normal and is part of the paint curing process. It is
recommended that you open a few windows to ventilate the
room. This will be noticeable for at least 6 hours. During the
first hour smoke detectors in the house may be set off.
♦
Following the initial burn-in period, the glass panel may
require cleaning.
♦
CAUTION: Do not clean the glass when the appliance is
hot!
♦
When the appliance is fired from cold the glass may fog up.
This is due to condensations and is normal.
♦
Make yourself familiar with these instruction before operating
the appliance.
♦
Check any loose electrical wires that may cause a shock.
♦
Check around the appliance for gas leaks. IF YOU SMELL
GAS, follow the instructions on the front cover of this
manual.
♦
Check to see that logs are correctly positioned. The pilot
light should be visible.
♦
Check to make sure that venting is secure.
♦
Check all external parts, such as grills, doors and control
cover are properly attached and fastened.
♦
CAUTION: Do not turn the unit off and on again within a
minimum of a 60 second wait.
FOR YOUR SAFETY READ - BEFORE LIGHTING
WARNING:
WARNING:
WARNING:
WARNING:
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY AND/OR PERSONAL INJURY
FINAL CHECK
INSTALLER: Before leaving the appliance with the customer,
you must check the operation of the appliance:
♦
Thoroughly check the entire appliance for gas leaks.
♦
Check correct rating by clocking the appliance at 15
minutes (see label).
♦
Check flame picture. Adjust primary air if required (see
page 14).
♦
Take time to go through the unit with the customer.
Содержание 2205
Страница 9: ...DATE PRINTED 2 8 05 Revision Date 04 15 04 OM 2205 Page 9 CLEARANCES TO COMBUSTIBLES ...
Страница 16: ...DATE PRINTED 2 8 05 Revision Date 04 15 04 OM 2205 Page 16 SHROUD KIT GRILL ROD KIT INSTALLTION ...
Страница 31: ...DATE PRINTED 2 8 05 Revision Date 04 15 04 OM 2205 Page 31 NOTES ...