DATE PRINTED: 2/8/05 Revision Date: 04/15/04
OM-2205 Page 22
MAINTENANCE
FREQUENCY OF SERVICE
♦
Regularly:
Clean and remove any lint accumulations or
debris from the grills and in any combustion and convection
air passage ways.
♦
Keep the appliance area free from combustible materials,
such as paper, wood, clothing, gasoline, flammable solids,
liquids and vapors.
♦
Visually check the height and color of the burner and pilot
flames.
♦
Check for unusual noise, odor and operation of the
appliance.
♦
Check the vent terminal for any damage, or obstruction by
plants or debris accumulation.
♦
Once a Year:
Open the door assembly and clean the inside
of the glass with a soft, non-abrasive cloth and water or a
suitable, mild, non-abrasive cleaner.
♦
Carefully remove the logs and gently brush off any loose
carbon deposits. This job is best done outside the house,
wearing a dust mask.The logs are very fragile, take care not
to break them. After cleaning, the logs must be replaced as
per the instructions in this manual.
♦
Have a qualified service technician:
Completely inspect
the appliance and the venting system.
♦
Clean and remove any lint accumulations or debris in the
firebox, on the burners, on the pilot, at the primary air
opening, on the convection air blower and in any combustion
and convection air passage ways.
♦
Check the safety system of the gas valve by lighting the unit,
with the door open and blocking the flame to the thermocou-
ple, the valve should act to shut the gas off in approximately
30 seconds.
CAUTION: NEVER CLEAN THE APPLIANCE WHEN IT IS HOT. ANY SAFETY SCREEN OR GUARD REMOVED
FOR SERVICING MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE. DO NOT USE
ANY SUBSTITUTE MATERIALS.
♦
VENTING:
1.
Check the venting system for any signs of corrosion.
2.
Remove the vent termination and check the inside of the
vent by shining a light down the pipe.
3.
Inspect pipe seams and joints and ensure they are still tight.
4.
Check wall straps and all vent supports.
NOTE: The surround may be removed to gain better access
to the appliance venting.
♦
LOGS:
♦
Check logs are correctly positioned (see installation instruc-
tions).
1.
Check there are no cracked logs.
2. Clean off any soot deposits using a soft brush.
NOTE: Incorrect log positioning may cause carbon build up
and discoloration. This may void the warranty.
TECHNICAL INSTRUCTIONS
♦
PILOT ASSEMBLY:
The correct flame pattern should have
three strong blue flames. One flows around the thermopile,
one around the thermocouple/ back tube of burner and one
flows over the front burner.
Pilot Flame Should Look Like
This
Top View Of Burner
Thermopile
Pilot
PILOT ASSEMBLY: