OM-2205                                                                                                         Page 13 

INSTALLATION 

 

PIPING DETAIL 

       

Gas Connection: 

The gas connection supplied is a 1/2” flare connection. The supply pipe can be either  rigid or listed flexible connection 

and/or copper tubing if  allowed by state, provincial and local codes. 

In the USA follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1. 

In Canada consult local  authorities and the CAN/CGA B149 installation codes. 

Provide a union downstream of the appliance shut-off valve to allow disconnection of the burner assembly for servicing. 

IMPORTANT: 

 

Always check for gas leaks with soap and water solution or gas leak 

detector. Do not use open flame for leak detection. 

High Altitude: 

In  the  USA  the  model  2205  is  approved  for  altitudes  up  to  2000  feet  using  the  factory  installed  burner  orifice.  At 

elevations above 2000 feet, U.S. codes require a decrease in the input rating by replacing the burner orifice. The input 

should be reduced by 4% for each 1000 feet above sea level (see appendix ‘A’). Check local gas utility for orifice size 

identification.   

 

In Canada the model 2205 is approved for altitudes up to 4,500 feet (1375 meters). For altitudes above 4,500 feet 

(1375 meters) consult the local codes for correct de-rating.

 

Note: The difference in altitude rating   is a requirement of certification standards. 

Natural Gas 

Minimum 5.0”w.c 

Maximum 10.5”w.c 

Recommended 7”w.c 

LP GAS 

Minimum 12.1”w.c 

Maximum 14.0”w.c 

Recommended 12.5”w.c 

GAS SUPPLY PRESSURE 

Содержание 2205

Страница 1: ...phone Follow the gas supplier s instructions If you cannot reach the gas supplier call the fire department PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND OPERATING THE APPLIANCE WARNING If the information in these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Installation and service must be performed by a qua...

Страница 2: ...X A HIGH ALTITUDE 25 APPENDIX B CONVERSION KITS 26 APPENDIX C WARRANTY 27 28 APPENDIX D TROUBLE SHOOTING 29 30 Page Mail your warranty card TODAY and SAVE your BILL OF SALE This card is included with the accessory package inside each firebox In order to receive full warranty coverage and to expedite service BKI recommends that you save your bill of sale and attach it to this page By doing this you...

Страница 3: ...ensive warranty policy LISTING AND CODES The Blaze King Model 2205 is listed and certified for installation in the U S A and Canada under the following standards ANSI Z21 88 CGA 2 22 2002 Vented Gas Fireplace Heater CAN CGA 2 17 M91 Gas Fired Appliances for Use at High Altitudes Please contact Blaze King if you have any questions regarding the certification of this appliance BUILDING AND FIRE CODE...

Страница 4: ... fil d alimentation électrique dessous la chauffrette Part No 0719B fan or blower assembly may be used For installation in masonry fireplaces or any factory built fireplace listed to ULCS 610 in Canada UL 127 in the United States This stove is factory equipped for 0 610m 0 2000 ft in the United States Cette chauffrette est equipe en usine pour une elevation de 0 à 610m 0 2000 pi This stove is fact...

Страница 5: ...m Electrical Rating 120 V A C System 120 V A C System Circulating fan Variable Speed Variable Speed Vent System Bi axial 3 liner Bi axial 3 liner Log Set Ceramic 4 Piece Ceramic 4 Piece HIGH ALTITUDE INSTALLATION When installing this appliance over 4500 ft 1372 m above sea level in Canada the appliance must be properly de rated and installed according to local codes in the absence of local codes i...

Страница 6: ...DATE PRINTED 2 8 05 Revision Date 04 15 04 OM 2205 Page 6 APPLIANCE DESCRIPTION DIMENSIONS APPLIANCE DIMENSIONS ...

Страница 7: ...cted to a line voltage electrical supply Any safety screen or guard removed for servicing a room heater must be replaced prior to operating the appliance Installation and repair should be done by a qualified service person The appliance and venting should be inspected before use by a qualified person and have inspections by a qualified service person annually More frequent cleaning may be required...

Страница 8: ...t gas pressure is required to supply the unit with a minimum of 5 0 W C for natural gas and 12 0 W C for LPG see gas installation on page 12 13 Allow adequate accessibility clearances for servicing and proper operation A suitable power outlet is required to provide power to the fan PLANNING YOUR INSTALLATION PLANNING YOUR INSTALLATION CAUTION This appliance is designed for use in a factory built s...

Страница 9: ...DATE PRINTED 2 8 05 Revision Date 04 15 04 OM 2205 Page 9 CLEARANCES TO COMBUSTIBLES ...

Страница 10: ...enly spaced around the pipe Approximately 1 from the end of the 3 appliance exhaust pipe outlet at the appliance air intake pipe and at the 3 terminal connections apply a bead of Mil Pac or other high heat silicone 1 4 wide Slide the 3 pipe onto the appliance and secure with 3 screws evenly spaced to the outlet Only use approved 3 double walled flex liner for correct installation VENT ASSEMBLY Air...

Страница 11: ...or personal injury 30 FT MAXIMUM VERTICAL RISE MINIMUM 8 FT Intake Connector Exhaust Connector The model 2205 is only certified for vertical terminations VENT TERMINAL CLEARANCES 2FT MAXIMUM HORIZONTAL RUN This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Refractory material glass doors screen rails screen mesh and log grates can be removed from...

Страница 12: ...sufficient volume will be supplied to the appliance Provide adequate clearance for proper installation and checking of the gas connections Have your gas supplier or a qualified gas fitter run a gas supply line into the gas fireplace The line must be properly sized and fitted according to the installation codes Up stream of the appliance supply connection the fitter shall provide an easily accessib...

Страница 13: ... or gas leak detector Do not use open flame for leak detection High Altitude In the USA the model 2205 is approved for altitudes up to 2000 feet using the factory installed burner orifice At elevations above 2000 feet U S codes require a decrease in the input rating by replacing the burner orifice The input should be reduced by 4 for each 1000 feet above sea level see appendix A Check local gas ut...

Страница 14: ...tem and is not intended to be connected to main power If required a wall thermostat may be installed Blaze King provides a thermostat but any CSA ULC or UL approved 250 750 millivolt rated non anticipator type thermostat may be used It is important to use the correct gauge wire when installing your thermostat Note When installing a remote control or wall switch use the correct gauge of wire See ta...

Страница 15: ...ttach to the unit with all remaining screws it might be necessary to loosen some of the mounting brackets where attached to the shroud to allow for some screw hole alignment Now reinstall the viewing glass and the glass retainer see page 17 The next step is to mount the upper and lower grill rod kits They are fasten with 2 screw per side to the grill mounting brackets as shown above Note that the ...

Страница 16: ...DATE PRINTED 2 8 05 Revision Date 04 15 04 OM 2205 Page 16 SHROUD KIT GRILL ROD KIT INSTALLTION ...

Страница 17: ... until they are replaced LOG INSTALLATION TO OPEN DOOR 1 2 3 4 5 6 Door Installation To install door slide bottom door lip into bottom door re tainer bracket The next step is to lift the door slightly into place and insert the door retainer tabs lo cated on each side of the unit into the slots at the top on each side of the door Pull the door out slightly at the top and release to en sure that the...

Страница 18: ... terminals TP TH to test ancillary switching Observe good wiring practice Label all wires prior to disconnection when servicing controls Wiring errors can cause damage to the unit and may cause dangerous operation Verify proper operation after servicing Honeywell Valve Blower Thermostat Cordset Ground Blower Control Blower Piezo Push Button Ignitor TH TH TP TP TH WARNING Electrical Grounding Instr...

Страница 19: ...so the Honeywell valve is equipped with a safety lockout once in the off position you must wait until the thermopile has cooled down before attempting to light the pilot approximately 3 minutes 4 Press and turn control knob counterclockwise to ON position 5 Turn flame and heat adjustment knob to the desired comfort level from HIGH to LOW 6 Turn thermostat to the desired comfort level or turn ON OF...

Страница 20: ...ounds on start up and shut down This is due to the expansion and contraction of the steel in the firebox BLOWER We use high efficiency fans in our appli ances You may hear a whirring sound when the fan turns on This will decrease or increase depending on the speed setting of the fan PILOT FLAME You may detect a very slight whisper sound from the pilot when it is turned on These are all normal soun...

Страница 21: ...ld be avoided 4 Our dealers have had good results from the products listed below We can not however guarantee the results of these products a BRASSO b POLISH PLUS by KEL KEM c COOK TOP CLEAN CREME by ELCO d WHITE OFF by RUTLAND NOTE This is a problem beyond Blaze King s control and is not covered under warranty IMPORTANT WHITE MINERAL DEPOSITS When using any gas appliance LPG or NAT Gas water is a...

Страница 22: ...ary air opening on the convection air blower and in any combustion and convection air passage ways Check the safety system of the gas valve by lighting the unit with the door open and blocking the flame to the thermocou ple the valve should act to shut the gas off in approximately 30 seconds CAUTION NEVER CLEAN THE APPLIANCE WHEN IT IS HOT ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING MUST BE R...

Страница 23: ...e terminals 9 Pull the blower assembly through the firebox through the door Be careful you do not snag and damage the electrical connections 10 Replacing the assembly is the reverse of the above Instructions GAS VALVE REPLACEMENT 1 Disconnect electricity to the appliance 2 Shut off the gas to the appliance and disconnect the gas line to the appliance 3 If the appliance has a remote switch or therm...

Страница 24: ...as Valve Honeywell 0720VC Piezzo Push Button Igniter R S only 0737 Main Burner Switch 0725 Right Twig 9869R Left Twig 9869L Wall Thermostat 0736 Squirrel Cage Fan 0719B Rear Brick Panel 9865 Left Brick Panel 9866 L Right Brick Panel 9866 R F 160 Fan Snapdisk 1150 Rheostat c w Knob Z0137A Thermopile Generator 0721A Electrode c w Wire 0738B Shroud Kit Z2223 LPG Conversion Kit Z0771H ...

Страница 25: ...APPENDIX A HIGH ALTITUDE CHART Equivalent Orifice Sizes at High Altitudes per the current edition of ANSI Z223 1 Includes 4 input reduction for each 1 000 feet NATURAL GAS AND PROPANE ORIFICE REQUIRED AT INCREASED ALTITUDE THIS CHART IS BASED ON A CALORIFIC VALUE OF 1000 BTU FOR NATURAL GAS AND 2500 BTU FOR PROPANE In Canada the appliance is certified for use with a number 36 natural gas 53 propan...

Страница 26: ... gas orifice 6 Carefully unscrew the pilot assembly 2 screws and re move the pilot orifice and replace with alternate pilot ori fice 7 Convert the gas valve See the separate gas valve manufacturers instructions supplied in the kit 8 Fill out conversion sticker supplied in conversion kit The model 2205 is designed to burn either Natural Gas or Propane LP Fuel Each heater leaves the factory equipped...

Страница 27: ...not cover any charges relating to labor This portion of the warranty coverage is not transferable and applies only to the original purchaser How to Get Service If this product requires repair or replacement due to defects in material or craftsmanship during the first five years of ownership contact your Blaze King dealer and explain the nature of the problem If the dealer is unable to repair or re...

Страница 28: ...retion In no event shall Blaze King be held responsible for indirect or consequential damages of any nature which are in excess of the original purchase price of the product Blaze King may at its discretion discharge any or all obligations by refunding the wholesale price of any defective part or parts Misuse of Stove Nullifies Warranty The above warranty is conditional upon the proper installatio...

Страница 29: ...he flame is too small check for correct gas supply pressure If pressure is good adjust the pilot flame size with the adjustment screw on the valve If the flame cannot be adjusted there might be some debris obstructing the pilot orifice Check for correct millivolts at the thermopile The thermopile should generate at least 250 mV Check for correct millivolts at the thermocouple The thermocouple shou...

Страница 30: ... Incorrect aeration adjustment Incorrect venting Check aeration setting Check that venting is correctly attached Sharp blue flames lifting off burner Incorrect aeration adjustment Reduce primary aeration adjustment Convection blower does not operate No power supply Thermal snap switch lose or defective Lose electrical connection Defective speed controller Defective blower Check electrical supply t...

Страница 31: ...DATE PRINTED 2 8 05 Revision Date 04 15 04 OM 2205 Page 31 NOTES ...

Отзывы: