SmartPath AP Safety Compliance
Danish:
Undertegnede Black Box erklærer herved, at følgende udstyr Radio LAN device overholder de væsentlige krav og øvrige
relevante krav i direktiv 1999/5/EF.
German:
Hiermit erklärt Black Box, dass sich dieser/diese/ dieses Radio LAN device in Übereinstimmung mit den grundlegenden
Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet". (BMWi) Hiermit erklärt
Black Box die Übereinstimmung des Gerätes Radio LAN device mit den grundlegenden Anforderungen und den
anderen relevanten Festlegungen der Richtlinie 1999/5/EG. (Wien)
Italian:
Con la presente Black Box dichiara che questo Radio LAN device è conforme ai requisiti essenziali ed alle altre disposizioni
pertinenti stabilite dalla direttiva 1999/5/CE.
Spanish:
Por medio de la presente Black Box declara que el Radio LAN device cumple con los requisitos esenciales y cualesquiera
otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE.
Portuguese:
Black Box declara que este Radio LAN device está conforme com os requisitos essenciais e outras disposições da
Directiva 1999/5/CE.
SmartPath AP Safety Compliance
Power Cord Safety
Please read the following safety information carefully before installing a SmartPath AP:
WARNING: Installation and removal of SmartPath APs must be carried out by qualified personnel only.
• SmartPath APs must be connected to a grounded (earthed) outlet to comply with international safety standards.
• Do not connect SmartPath APs to an AC outlet (power supply) without a ground (earth) connection.
• The appliance coupler (the connector to the unit and not the wall plug) must have a configuration for mating with an EN
60320/IEC320 appliance inlet.
• The socket outlet must be near the SmartPath AP and easily accessible. You can only remove power from a SmartPath AP
by disconnecting the power cord from the outlet.
• SmartPath APs operate under Safety Extra-Low Voltage (SELV) conditions according to IEC 60950. The conditions are only
maintained if the equipment to which they are connected also operates under SELV conditions.
• A SmartPath AP receiving power through its Power over Ethernet (PoE) interface must be in the same building as the equipment
from which it receives power.
France and Peru only:
SmartPath APs cannot be powered from IT* supplies. If your supplies are of IT type, then a SmartPath AP must be powered by
230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point labelled Neutral, connected directly to
ground (earth). *Impédance à la terre
IMPORTANT: Before making connections, make sure you have the correct cord set. Check it (read the label on the
cable) against the description in this section.
U.S.A. and Canada only:
• The cord set must be UL
®
and CSA certified.
• Minimum specifications for the flexible cord:
- No. 18 AWG, not longer than 2 m, or 16 AWG
- Type SV or SJ
- The cord set must have a rated current capacity of at least 10 A.