INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Pellet burner Bisolid GP xx R tsc OM-BSGPRTSCV00/11/2016/EN
22
5.10.3. INFORMATION ON ALARM MESSAGES
The presence of an alarm message on the pellet burner is indicated by an icon .
Table 7. Information on alarm messages
ОК
– normal condition, Err – alarm message.
In case of a warning alarm message Air flow, meaning it is activated
connected pressure switch or injured fan for fresh air.
In case of a warning alarm message for the failure of the pellet burner, the user
is obliged to check for possible accumulation of fuel in the burner tube and fuel
transport auger and in the presence of fuel to remove it.
5.11. SERVICE SETTINGS
When using the service controller settings of the pellet burner, access is performed by a
password. The password is activated again after exiting of the menu, if within 15 sec. button is
not pressed.
The procedures for service settings of the pellet burner are protected by
password and can be used only for trained service specialists that have
additional information.
Name
Designation
Condition
Recovery
No flame
No Fire
OK / Err
Switch off and on
Danger of frost
Low Tb
OK / Err
Increasing of
temperature
Overheat
(activated blocking
thermostat)
In BT
OK / Err
Switch off and on
No airflow
(device for flow)
Air flow
OK / Err
Switch off and on
Alarm
No Fire
OK
Low Tb
OK
In BT
OK
Air flow OK