monitoring.
or repaced – to be performed by
servicing specialist only.
The burner does not
start or stops operation.
No power supply.
Check if the burner display and its
indication operate. Check working
order of the appliance power supply, to
which the burner is installed and
powers it with voltage 230 VAC, 50 Hz
– to be performed by servicing
technician. Check burner correct
wiring, according to the presented
wiring diagram. Check for loose
electrical connections – to be
performed by servicing technician.
No start signal to the burner.
Check if the burner has received start
signal and if the module, providing
signal for operation to the burner,
wiring is in working order – to be
performed by servicing technician.
Check for loose electrical connections.
Check the working order of the burner
operation control module, which
provides voltage and necessary
signals.
The burner does not operate even
if there is operation signal.
Check for activated emergency alarm
– check the alarm messages.
Blown fuses.
To be performed by servicing
technician: check the fuses condition
and if there is necessity for
replacement, then change the fuses
with the same corresponding
parameters (Warning: the fuses are
fast-reacting).
The flame from the
burning process is
“dim”and the chimney
smokes much.
Wood pellets with low quality.
It is necessary to change the pellets,
as possibly their water content is
higher then the normal needed for the
burner operation.
Unsuitable adjustment of the
burner parameters.
Adjustment of the appliance operating
parameters is necessary – to be
performed by specialist.
The burner starts but it
can not reach to
stabilized condition.
Incorrectly positioned photo-
sensor.
Change the photo-sensor, used for
burning process monitoring, position
by rotating it around its longitudinal
axis.
The photo-sensor surface is dirty.
Clean the dirts carefully.
The photo-sensor is damaged –
there are burnout traces on its
surface.
It is necessary to replace the photo-
sensor with new one – ask for service
assistance. Reason – incorrect burner
switch off.
Unstable operation of
the burner.
Photo-sensor failure.
Check photo-sensor working order.
Controller operation settings are
changed.
Check the burner heating output level
setting.
Check the controller settings – to be
performed by servicing technician.
Excess heating of the
burner’s pellet inlet pipe.
Insufficient chimney draught or
presence of dirt.
It is necessary to clean the appliance
and the chimney if necessary. Possible
solution is to install flue gas extractor
fan or/and change the chimney.
Heating of the burner’s
pellet inlet pipe and
emergency thermostat
Low chimney draught or the
appliance is contaminated with
dust particles.
It is necessary to clean the appliance
and the chimney, if necessary. It is
necessary to restart the burner.