INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Pellet burner Bisolid GP xx R tsc OM-BSGPRTSCV00/11/2016/EN
32
6. INSTALLATION INSTRUCTIONS FOR PELLET BURNER SERIES
BISOLID GP XX R TSC
6.1.
TUBE
PELLET
BURNER
INSTALLATION
–
COMMON
INFORMATION
The rotary tube pellet burner series Bisolid GP xx R tsc must be installed only by specialized
company, authorized for such activities. The pellet burner installation must be performed
depending on the solid fuel hot water boiler with sufficiently high efficiency, the preliminary
designed project and acting legal provisions.
The existing networks of authorized service organizations comply with these conditions and
are able to take responsibility for all pellet burners Bisolid GP xx R tsc (models GP 25 R tsc,
GP 35 R tsc, GP 45 R tsc and GP 60 R tsc), installations, their initialization in operation and
warranty repairs.
Installation of the rotary tube pellet burner must comply with the acting regulations and
directives as well as to the operation and installation manual. The manufacturer is not
responsible for failures or damages caused by unqualified installation.
The rotary tube pellet burner series Bisolid GP xx R tsc must be connected to
the power supply only by qualified authorized person.
All problems (failures) caused by incorrect installation of the rotary tube pellet
burner are not covered by the pellet burner’s warranty cards.
The manufacturer makes the following recommendations during installation of the control
elements:
Temperature sensor To of heating water, have to be mounted on the outlet hot water
pipe from the boiler.
Temperature sensor for flue gases T_flue gas, have to be installed at the exit from the
boiler gas duct pipe to the chimney.
Room thermostat, have to be installed in the room in places protected from direct
sunlight and internal heat sources (household appliances, audio - video equipment,
etc.).
The main module of rotary tube pellet burner with self-cleaning series Bisolid GP xx R tsc is
mounted in the position showns in Figure 12 to the equipment that will consume heat energy
(boiler), generated by fuel combustion.
Before taking action on cleaning, servicing and repair, the pellet burner must
be switch off from the electricity supply.