INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Pellet burner Bisolid GP xx R tsc OM-BSGPRTSCV00/11/2016/EN
34
6.2. CHOOSING OF A ROTARY TUBE PELLET BURNER
The choice of suitable rotary tube pellet burner series Bisolid GP xx R tsc is necessary to be
made accordingly to the heating output of the different types and models solid fuel hot water
boilers. The correctly chosen pellet burner used for installation to the mentioned hot water
solid fuel boilers guarantees economic and optimum operation of the system boiler – burner.
The choice of pellet burner with too high nominal heating output, compared to the boiler’s
output, leads to increased consumption and fuel expences.
The choice of pellet burner with much lower nominal heating output, compared to the boiler’s
output, leads to impossibility for reaching the boiler’s nominal parameters and low efficiency.
6.3. POSITIONING OF THE ROTARY TUBE PELLET BURNER
The rotary tube pellet burner series Bisolid GP xx R tsc can be installed on hot water boilers,
which are positioned in uninhabitable premises (for example boiler room, basement).
The tube pellet burner and boiler room must have constant fresh air intake, needed for the
burning process. The air has to be clean, without halogen hydrocarbons, corrosive vapors and
should not be too wet and dusty. The room must be protected against freezing, with ambient
temperature in the range from +5°C to +35°
С
and with no more than 80% relative humidity of
the air.
Safe 200 mm distance must be kept in the cases when the flammability level of the material is
unknown. The same safety distance must be kept also for domestic objects, flammable
materials and fuels situated in the room, where the burner is positioned.
Do not put flammable materials over burner’s main module top side or near it
within the safety distance.
The main module of the rotary tube pellet burner series Bisolid GP xx R tsc must be installed
in horizontal position towards a suitable solid fuel hot water boiler. The pellet burner position
has to be considered so it can provide its reliable operation, easy cleaning, handling and
servicing. Correct positioning during the pellet burner installation guarantees reliable and
efficient parallel operation of the burner and the hot water boiler.
The fuel transport auger must be installed near to the already installed pellet burner, in order
to secure its good connection, through the flexible pipe, with the burner’s main module fuel
supply pipe.
If the fuel transportation auger’s angle changes, then the wood pellet
consumption changes respectively depending on the pellet burner heating
ouput.