In case of a warning alarm message for the failure of the pellet burner, the user
is obliged to check for possible accumulation of fuel in the burner tube and fuel
transport auger and in the presence of fuel to remove it.
5.17. DISMANTLING AND MOUNTING OF A PELLET BURNER
ROTATION TUBE
The time for cleaning (rotating tube) of the combustion chamber of rotary tube pellet burner
Bisolid GP xx R tsc and cleaning the tube itself depends on the type and quality of the used
fuel.
Before taking action on cleaning, servicing and repair, the pellet burner must
be switch off from the electricity supply.
When cleaning the tube of pellet burner Bisolid GP xx R tsc need to be removed combustion
head of the burner, as shown in the diagram in the following figure.
Figure 10. Diagram of the burner main module with dismantling tube
The tube of pellet burner is removed after cooling of the base module so that
be safety in tube handling in its cleaning. During the cleaning should pay
particular attention to overall cleaning of the holes through which air supply
and that provides efficient combustion process and optimum cooling
.
The ash cleaning from the burner and boiler and also removal of the ash
container must be performed by personal safety means (cloves and cuffs).
We recommend in dismantling and mounting works to be used respective
tools.