INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Pellet burner Bisolid GP xx R tsc OM-BSGPRTSCV00/11/2016/EN
21
Table 5. Parameters of pellet burner user’s settings
5.10.2. WEEKLY TIMER
Table 6. Parameters of weekly timer settings
To operate the controller must be set interval to work at least one of the four
programs. When set to the same start and end time of the interval program is
inactive.
Switchng off on weekly timer is indicated by Pr.0, at work displays the number of the relevant
active program (Pr.1 - Pr.4).
Name
Designation
Limmits
Factory setting
Assignment for:
Water temperature (manual)
Room thermostat – time for
optimisation
(depends on „Type control”)
Tb set
Rth delay
Tmin – Tmax °C
0 – 60 min
80 °C
0 min
Assignment sensor light
Fire set
0 – 99 %
50 %
Assignment flue gases
temperature
Tfg set
0 – 250 °C
40 °C
Assignment switch on pump
Tpump set
10 – 70 °C
10 °C
Current time and day
time&d
hh/mm/d
Language
Language
Eng /
Бъл
Eng
Name
Designation
Limmits
Program number
Program
1 - 4
Interval
00:00 – 24:00
Day of the week
SuMoTuWeThFrSa
Su – Sa
(from Sunday to
Saturday)
Weekly timer
*Program 1
00:00 to 24:00
SuMoTuWeThFrSa
EXIT