5.10. OPERATION (FUNCTIONING) OF THE PELLET BURNER
In this part of the operation manual is presented information only for the users.
The information for servicing specialists is presented separately.
The controller of the tube pellet burner is swithcing on and off:
By pressing and holding the button ON/OFF. When the burner is swithc off then
appears "Stopped".
In the off position when on the display shows one of the above messages by pressing
and holding for about 10 seconds on the button „ ” can be switched on and off in
manual way pellet auger with aim filling when the auger is empty.
Before manually switching on of pellet burner you have to verify that the burner
is burnt out.
With buttons „ ” or „ ” scroll until on the display is shown the menu with the desired
parameters, then press „ ”:
For choice of settings, scroll move the cursur „*” with buttons „ ” or „ ” to make
change and return to choice of settings press button „ ”.
The setting which changes startsto blink, with buttons „ ” or „ ” you can change the
net value.
After completing the settings, select „EXIT” and press button „ ” to save the
changes.
The controller (the pellet burner) can be switched on or off by the front panel or
by the remote control electrical input. The remote control input is usually
connected to a START key with two resistant positions. WE RECOMMEND
THAT THE BURNER IS SWITCHED ON OR OFF BY THIS START KEY!
The controller switches off no matter which source sends STOP command, but
can be switched on only when there is START command on both places.
5.10.1. USER’S SETTINGS
User’s Settings
*Troom set
22°C
Fire set
50%
Tfg set
80°C
Tpump set
30°C
User’s Settings
time&d 08:30 Fr
Language Eng
EXIT