![BiSolid GP 25 R tsc Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/bisolid/gp-25-r-tsc/gp-25-r-tsc_installation-operation-and-maintenance-manual_2757148033.webp)
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Pellet burner Bisolid GP xx R tsc OM-BSGPRTSCV00/11/2016/EN
33
During the servicing of a rotary tube pellet burner the end user must use
personal protective means (gloves) and the relevant technical tools.
Figure 12. Installation diagram of a rotary tube pellet burner series Bisolid GP xx R tsc
Depending on the equipment it is necessary to be prepared technical evaluation of the project
for installation of the main module, so as to ensure its reliable operation, easy cleaning,
servicing and maintenance. The main module of pellet burner is mounted to the equipment -
heat consumer using thermal insulation.
The transport auger for fuel is placed near the burner so that it can be connected to the main
module by the flexible pipe through which the fuel from the auger will be transported. It is also
advisable to position the angle between the horizontal plane and the axis of the auger is 45
o
,
which will ensure optimal operating conditions for the electric motor of the auger and the
combustion process.
Change of the auger’s tilting angle leads to changes in the fuel consumption
and respectively to the burner’s heating output:
- Decreasing the auger’s tilting angle leads to increased fuel
consumption, respectively to increased heating output.
- Increasing the auger’s tilting angle leads to decreased fuel
consumption, respectively to decreased heating output.
Fuel auger
Lid
Washer
Nut
Lid
Boiler