Operation Manual BioSmart PV-WM v.029.1|03.2021|en
Page 9 of 24
BioSmart PV-WM Reader
Operation Manual
Table 4
–
Jumper description
Designation
Purpose
IP RST
Reset the IP-address setting
BOOT
(Х2)
The reader transition into debug mode
Jumper BOOT (X2) is intended to switch the reader to debug mode (bootloader). This mode allows to
restore the reader operability if the firmware is damaged. To put in debug mode, close the BOOT (X2) jumper
when the power is off and turn on the reader power. Two seconds after turning on the reader power supply,
open the contacts.
In debug mode, the green RUN LED on the reader board blinks with a period of 1 sec (0.5 sec on, 0.5
sec off).
The reader may be powered from the BioSmart UniPass controller via an Ethernet cable using PoE
technology, or from a 12V DC voltage source connected to the clips on the reader board.
To power the reader from a DC voltage source, connect the "+" (plus) of the power supply to clip 2 on
the reader board, and s
ource “
-
” (minus)
- to clip 1.
The recommended type of power cables and their length are shown in Table 5.
Table 5
–
Recommended power cable types
Power supply
method
Maximum
length, m
Cable type
Ethernet (IEEE 802.3)
100
A cable consisting of four twisted pairs of a category
not lower than the fifth with a cross-section of each
wire not less than 0.2 mm
2
Power supply cable
50
Double-core cable with a cross-sectional area of each
core not less than 0.75 mm
2
Power supply from a DC voltage source is carried out at a voltage of 12V with an output current of 1A.
The allowable range of the supply voltage is 10.2 - 13.8V. To prevent the device from malfunctioning due to
incorrect power connection, a protective diode is provided in the circuit board.
The BioSmart PV-WM readers are connected to the BioSmart UniPass controller via the Ethernet
interface.
Measuring instruments, tools and accessories
Installing the reader requires the following tools and accessories, listed in Table 6.
Table 6
–
The list of tools and tackles
No
Names of tools and tackles
Notes
1
8P8C connector
For mounting the connector ("crimping") of
the Ethernet cable
2
С
rimping tool for Ethernet cables
3
Crosshead screwdriver
To lift off the cover and install the back cover
of the reader
During the operation of the reader, measuring instruments, tools and accessories are not required.
Marking and Sealing
The reader board is marked with element designations and the manufacturer's logo.
The warranty seal is installed on the reader board.
A serial number label is located on the inside of the scanner bowl and on the back of the reader, next
to the metal mounting plate.
There is a manufacturer's label on the back cover of the reader under the mounting plate. The
packaging is marked with transport markings containing handling symbols: