Maintenance for Intended Usage
Maintenance of the device consists in systematic monitoring of its correct operation, regular technical
inspection and troubleshooting.
Maintenance is carried out at intervals of once a quarter.
Maintenance includes:
remove dirt and dust from the palm vein scanner with a soft dry cloth without the use of
chemicals;
check of fastenings of connections, connectors;
checking the indication of the operating modes of the device;
checking the log of emergency events in Biosmart-Studio v5.
The frequency of removing dust and dirt from the scanner depends on the operating conditions (as
the scanner becomes dirty, dusty).
4
Miantenance
Repair and replacement of reader elements should be carried out only by specialists authorized by
the manufacturer of this reader.
5
Storage and Transortation
The packaged BioSmart devices transportation may be carried out by any means of transport in
covered vehicles. Transportation conditions by the influence of mechanical factors include transportation by
road with a total number of transshipments no more than four.
Transportation by various types of transport:
by air, by rail in combination with each other and with road transport with a total number of
transshipments from 3 to 4;
by waterway shipment (except for the sea) together with air shipment. Railway or road carriages
with a total number of transshipments no more than four.
Storage and transportation of BioSmart ACS should be carried out at ambient temperatures from
minus 40 to plus 50
С
.
ACS BioSmart should be stored and transported at a relative humidity of no more than 70%.
Storage and transportation of devices in the immediate vicinity of sources of heat and open fire is not
allowed to avoid overheating.
Storage and transportation of devices under conditions of ionizing (radiation) exposure is not allowed.
Storage of BioSmart devices in an aggressive environment (environment with acidic, basic or
oxidizing action and causing destruction (or deterioration of parameters)) is not allowed.
Storage and transportation of devices under the influence of biological factors, such as moldy fungi,
insects, animals, is not allowed.
For all types of transportation, packaged BioSmart ACS devices must be secured in a way that
excludes movement and impact, and the direct influence of atmospheric precipitation and aggressive
environments on BioSmart ACS devices must be excluded.
6
Utilization
BioSmart PV-WM reader mustn
’
t be utilized with household waste. At the end of use, contact a
certified collection point.