Operation Manual BioSmart PV-WM v.029.1|03.2021|en
Page 4 of 24
BioSmart PV-WM Reader
Operation Manual
1
Description of Reader Operation
Purpose
The BioSmart PV-WM reader is used as part of the BioSmart biometric access control and
management system in accordance with the BioSmart UniPass controller.
The BioSmart PV-WM reader is intended to read biometric data of a human palm vein pattern and
RFID-tag (card) code with subsequent transfer of the read information to the BioSmart UniPass or BioSmart
UniPass-EX controller via Ethernet.
The device is intended for use in premises, the operating conditions in which correspond to those
specified in this OM.
The device can be used outdoors if the following conditions are met:
installation is carried out in accordance with the requirements of this manual, taking into
account the provision of protection against dust and moisture penetration;
the reader is used in conjunction with a protective visor for
BioSmart PV-WM;
the operating conditions of the reader do not go beyond the operational limits (see par. 2.1).
Technical Characteristics
Technical characteristics are in the Table 1.
Table 1
–
Reader technical characteristics
Parameter
Value
Biometric ID
Palm vein
Biometric Scanner Type
Optical, infrared
Built-in RFID tag reader
Yes
Communication interface with the control computer
Ethernet (IEEE 802.3u,
100BASE-TX)
Maximum cable lenght Ethernet, m
100
Indicators
Buzzer and LED indicator
DC supply voltage, V
12 ± 15
%
Maximum consumed current, A
0,4
PoE support
IEEE 802.3af class 3
Case material
Palstic
Dimensions, mm
185 x 160 x 134
Net weight, g
550
Gross weight, g
880
Ambient temperature during operation, °С
From -40 to +50
The upper value of the relative air humidity during operation at
a temperature of 25
С
, %
95
Enclosure protection
IP65
Depending on the format of the RFID-tags (cards) used, appropriate versions of the readers are
provided. The list of versions is given in Table 2.
The list of RFID-tags formats read by BioSmart PV-WM, depending on the version of the reader, is
given in the reader's passport.
Table 2
–
List of the BioSmart PV-WM reader versions Construction
Execution
Note
BioSmart PV-WM-EM
For reading EM-Marine format card
BioSmart PV-WM-MF
For reading Mifare format card
BioSmart PV-WM-LG
For reading Legic format card
BioSmart PV-WM-IC
For reading HID iClass format card