KBF-LQC (E5.2) 12/2010
page 99/106
21.5 Equipment and options KBF-LQC
To operate the climatic chamber, use only original BINDER accessories or accessories / com-
ponents from third-party suppliers authorized by BINDER. The user is responsible for any risk
arising from using unauthorized accessories.
Regular equipment
Microprocessor display program controller with 2-channel technology for temperature and humidity, and
function Light Quantum Control
Ethernet interface for computer communication
Temperature safety device class 3.1 acc. to DIN 12880
Inner glass door with gasket
DCT™ refrigerating system with refrigerant R134a
Microprocessor controlled humidifying and dehumidifying system *) (humidity range, see diagram)
Four castors (2 lockable)
2 racks, stainless steel
Access port 30 mm with silicone plug
ICH compliant illumination for photo stability testing:
ICH light (light color 640 cool white + BINDER Q1B Synergy Light, 2 light cassettes
Spherical light sensors to measure illumination 0 kLUX up to 50 kLUX, and UV-intensity 0 W/m
2
up to 50
W/m
2
UVA
Options / accessories
Additional rack, stainless steel
Perforated shelf ,stainless steel
Reinforced rack with rack lockings
Securing elements for additional fastening of racks (4 pieces)
Light cassette
Set fluorescent tubes ICH light (light color 640 cool white + BINDER Q1B Synergy Light) for 1 light cas-
sette
Temperature safety device class 3.3 acc. to DIN 12880
Zero-voltage relay alarm outputs for temperature and humidity with DIN plug 6-poles
Keyboard locking (BINDER Individual customized solutions)
Lockable door
Interface RS422
BINDER Data Logger kit for temperature / humidity: TH 70 (chamber values) or TH 70/70 (chamber val-
ues and ambient values)
Flexible Pt 100 temperature sensor, output to DIN socket
External freshwater and wastewater cans (20 liters /
0.71
cu.ft.
each)
BINDER Pure Aqua Service
Exchange cartridge for BINDER Pure Aqua Service
Access ports 30 mm, 50 mm or 100 mm with silicone plug
Water protected internal socket 230 V AC (not for UL units)
Safety kit for water connection with hose burst protection device and reflux protection device, pre-
mounted assembly (BINDER Individual customized solutions)
Analog outputs 4-20 mA for temperature and humidity with 6 pole DIN socket, DIN plug included
Factory calibration certificate
Extension to factory calibration certificate (additional value)
Measurement and protocol according to DIN 12880