97
FLYNET 100
7
ERROR MESSAGES
7.1
Indicator errors
Problem
Cause
Remedy
The indicator does not turn
on by pressing the power
key
The blue LED is off
Check the status of the green LED on the power
supply unit:
if it is on, check the correct insertion of the
connector in point 9
The indicator does not
turn on
Wrong key press
Press on the logo in the centre of the key.
When pressed, you can feel the key cover being
pressed
Pressure on the touch
screen has no effect
Uncalibrated display
Switch the indicator off and on again.
Within 5 seconds of switching on press
anywhere on the display.
Perform the display calibration operations.
7.2
Scale Errors
Problem
Cause
Remedy
OVERLOAD
The scale is overloaded
Reduce the weight to a value lower than the
maximum capacity so that it is suitable to the
weighing area
UNDERLOAD
The scale is negative by at
least 20 divisions.
This message is only
displayed if the scale is
approved, otherwise, the
weight preceded by the '-'
character is displayed.
Press the reset key:
If the value does not reset to zero after pressing
the key:
1) switch off the instrument and repeat the
switching on operations;
2) inform the Service if the problem persists.
- -
Non-resettable weight
Unload the scale
- - - - - -
Unstable weight
Remove the cause of weight instability and try to
switch the indicator on again
- LOCK -
Instrument
not
reset
correctly
Unload the scale