22
FLYNET 100
DANGER
Check that:
•
The power supply line of the indicator has voltage and frequency as indicated on the
stamped plate on the indicator bottom;
•
The socket to which the indicator is connected is provided with grounding pin;
•
Warning and danger plates are present on the hood of the instrument;
•
If this is not the case, inform the maintenance personnel or our Service Department
directly.
Scale cable wiring
A pre-wired cable is normally supplied for connecting the indicator to the weighing platform.
Key
1. 9/15 pin male D-sub connector
2. Nut
3. Indicator back wall
4. Cable gland
5. Shielded shell (cap) with stamping screws
Figure 3.2-4 - Load cell connection
•
Insert the 9/15 pin connector in the scale input hole
•
Lock the cable gland with the nut.
•
Refit the shell with the drilled stamping screws.
•
Insert the connector on the bottom of the CPU housing.
The connection can be different depending on the type of cell that is fitted on the weighing platform:
analogue or digital. In case of duplex scale, scale A should be connected to JBIL1 connector, while scale B
should be connected to JBIL2 connector.
In case of triplex, scale C should be connected to JBIL3, while, in
case of quadruplex, scale D should be connected.
WARNING
The cable shield must always be connected to the metal protection cap of the 9/15 pin connector.
Do not insert the connection cable to the weighing platform into routes with cables directed to
power drives.