55
FLYNET 100
5.2.1.7 Scale Diagnostics Configuration
Scale Statistics
It records the number of times the weight loaded on the scale exceeds the
minimum weighing value. It is possible to view the data from Scale
Diagnostics Log, and a file is also generated in the system/statistics folder that
replicates the same data.
Scale Diagnostics
Enables/disables a Log file (e.g. 'diagerrorlog_1_000001.txt') that records the
scale events. It is saved in the default Extern folder. The report file is coded as
follows:
Date and Time
Separator ' ; ' (semicolon)
Scale board number
1, 2, 3, 4
involved
Separator ' ; ' (semicolon)
C1,C2,C3, ... , Cn
= Cell number
or
Bil
= Scale involved
Separator ' ; ' (semicolon)
ERROR TYPE
*
Scale/Cell not connected
!
Scale/Cell not connected occasionally
C
Scale/Cell not configured
M
Scale/ Cell serial number error
V
Scale/Cell voltage error
T
Scale/Cell temperature error
R
Reset cells (if Bil)/cell (if Cn)
W
Warmup
O
Overload
I
I2C internal bus error
Separator ' ; ' (semicolon)
Possible value
Log Folder
Allows selecting where to store the scale Diagnostics file. It is possible to
choose different sources including extern, USB or SD card.