11.4.
2 Submenu COM1
This sub-menu contains parameters concerning the COM1 serial ports.
BAUD
600, 1200, 2400, 4800, 9600, 19200, 38400,
57600, 115200
This parameter defines the baud rate, i.e. the
transmission/reception speed with which the
data leave or enter the COM1 / COM2 serial
ports.
BIT
Defines the format of the string data.
✔
7 E 1: 7 datum bits, parity even, 1 stop bit
✔
7 E 2: 7 datum bits, parity even, 2 stop bits
✔
7 O 1: 7 datum bits, parity odd, 1 stop bit
✔
8 N 1: 8 datum bits, no parity, 1 stop bit
✔
8 N 2: 8 datum bits, no parity, 2 stop bits
✔
8 E 1: 8 datum bits, parity even, 1 stop bit
✔
8 O 1: 8 datum bits, parity odd, 1 stop
bit
INTERF
RS232,RS422MRS485
Defines the hardware interface used to
transmit the string.
HANDSH
SOFT,NO
Handshake used for the serial port; set SOFT
for XON–XOFF