1-70
D70E
In the heading of the print, you may also see the serial number or MPP
terminal number, depending on the type of response selected during
installation.
10.4 Communication in MPP mode
10.4.1 Request weighing with key and transmit data at end
of operation
Place the load on the weighing platform,
wait for the stable weight indication to appear and press
.
The terminal will memorise data and transmit accordingly.
If you have selected
Std
in the
Setup Menu
, the following data will
be transmitted:
1st character
$(24H)
2nd character
M(4DH)
3rd character
P(50H)
4th-10th character
MPP identification
code or indications on
status of scale:
NO<SP>STAB weight is not
stable NO<SP>VAL<SP>
weight is not valid
ERRMEM<SP> weight
memorisation error
11th - 18th character
Weight with sign and decimal
separator
19th - 20th character
<um>
Unit of measurement
21st - 22nd character
<CRC>
String control field: this is
calculated with a XOR (or
exclusive) operation
involving all previous