PARAMETER
DIGIT VALUES
Ignition power
P 14
K value (external
probe diagram)
P 15
Regulation of the
minimum heating
power
P 16
D.h.w. burner turn off
function
P 17
NTC on the c.h. re-
turn
P 18
User interface
P 19
Not used
P 20
---------------
Not used
P 21
---------------
Not used
P 22
---------------
Not used
P 23
---------------
Not used
P 24
---------------
Not used
P 25
---------------
Not used
P 26
---------------
Minimum heating re-
turn temperature °C
P 27
Maintenance inter-
vals
P 28
D.h.w. entry temper-
ature for calculation
def=10
P 29
Correct pressure
main system (Pon)
P 30
Fig. 7.45
• Enter the ”programming mode” by press-
ing keys 12 - 15 - 16 (Fig. 7.46) for 10 sec-
onds at the same time until the letters
P01
are displayed on the LCD display and the
value of the parameter (40=Activ A Plus 16S
or 41=Activ A Plus 25S), indicating that ”pa-
rameter 01” (Fig. 7.47) has been activated.
Fig. 7.46
9
10
11
12 13
14
15
16
17
Fig. 7.47
• Scroll the various parameters using keys 15
or 16 until the letters
P02
are displayed on
the LCD display, indicating that ”parameter
02” has been activated.
• Press keys 9 or 10 to change the value and
confirm the value of the parameter with key
12.
• Press keys 15 or 16 (Fig. 7.46) to exit with-
out changing the value.
• Repeat all the above setting sequences in
order to visualize the parameters and their
values.
• Exiting the “programming mode” is auto-
matic, after 15 minutes, or by cutting power.