- 67 -
INST
ALLA
TION
COMMISSIONING
keys 12 - 15 - 16 (Fig. 7.43) for 10 seconds
at the same time until the letters
P01
are
displayed on the LCD display, indicating that
”parameter 01” (Fig. 7.42) has been acti-
vated.
Fig. 7.42
Fig. 7.43
9
10
11
12 13
14
15
16
17
• Scroll the various parameters using keys 15
or 16 until the letters
P12
are displayed on
the LCD display and the value of the param-
eter (100=Activ A Plus 16S and Activ A Plus
25S), indicating that ”parameter 12” (Fig.
7.44) has been activated.
Fig. 7.44
• It is possible to modify parameter using keys
9 or 10 (Fig. 7.43) (Refer to Fig. 7.41 and
determine the correct Value appertaining to
the output required for the central heating
requirement.).
• By pressing key 12 (Fig. 7.43) confirmation
of the inserted value is obtained.
• Press keys 15 or 16 (Fig. 7.43) to exit with-
out changing the value.
• Exiting the “programming mode” is auto-
matic, after 15 minutes, or by cutting power.
7.18 Setting record
Important: at the end of the setting opera-
tion it is important to fill/update the table
(Fig. 7.45).
This to allow a correct setting of this boiler
in case of replacement of the main control
p.c.b.
PARAMETER
DIGIT VALUES
Boiler type
P 01
Water sensors con-
figuration
P 02
Pump management
P 03
TA/OT zone manage-
ment
P 04
Gas type
P 05
Not used
P 06
---------------
C.h. flow max tem-
perature °C
P 07
Factory parameters
reset
P 08
Chimney
sweep
function
P 09
C.h. reignition fre-
quency
P 10
C.h. pump post-circu-
lation
P 11
Max. useful output in
c.h. mode
P 12
C.h. pump working
type
P 13