- 20 -
USE
USEFUL ADVICE
3
USEFUL ADVICE
3.1 Central Heating
For reasonably economical service install a
room thermostat. Never shut off the radia-
tor in the area where the room thermostat
is installed.
If a radiator (or a convector) does not heat
up, check that no air is present in it and that
its valve is open. If the ambient temperature
is too high, do not alter the radiator valves.
Reduce the central heating temperature in-
stead by means of the room thermostat or
by acting on the 15 and 16 heating adjust-
ment keys (Fig. 3.1).
Fig. 3.1
9
10
11
12 13
14
15
16
17
3.2 Frost protection
The anti-freeze system and any additional
protections protect the boiler from possible
damage due to frost.
This system does not guarantee protection
of the entire hydraulic system.
If the external temperature can reach val-
ues lower than 0°C, it is recommended that
the entire system is activated adjusting the
room thermostat at a low temperature.
The anti-freeze function is also activated
with the boiler in stand-by (Fig. 3.2).
Fig. 3.2
Therefore, when the boiler is not lit and
used in cold weather, with consequent risk
of freezing do not switch off the boiler at the
fused spur isolation switch or close the gas
inlet cock.
If the boiler is deactivated, have a qualified
technician empty the boiler (heating and
domestic hot water circuit), the c.h. system
and the d.h.w. system.
3.3 Condensate drain
The condensate drain must not be modi-
fied or blocked. Blockage of the condensate
drain, caused by debris or freezing, can
cause automatic shutdown of the boiler. If
freezing is suspected and the pipe run is ac-
cessible an attempt may be made to free
the obstruction by pouring hot water over
the exposed pipe an cleaning any blockage
from the end of the pipe.
If this fails to remedy the problem the assist-
ance of a Gas Safe registered installer or in
IE a competent person should be sought.
3.4 Periodic maintenance
For efficient and continuous operation of
the boiler, it is advisable to arrange mainte-
nance and cleaning by an Authorised Serv-
ice Centre Engineer, at least once a year.
During the service, the most important
components of the boiler will be inspected
and cleaned. This service can be part of a
maintenance contract. In particular, you are
Содержание Activ A 25S
Страница 79: ... 79 MAINTENANCE MAINTENANCE Fig 9 25 Winter ...
Страница 82: ... 82 NOTES ...
Страница 83: ......