1.
Turn the power switch on.
Then directly the controller is running.
Note: If the function code “rS” for Run/Stop by the panel is set
to “0”the controller is operated by “RUN/STOP” button.
When “RUN” lamp blinks the external operation signal on the terminal “P1” and “P2” or Overflow
sensor is set for stop even if “Run/Stop by Panel” is set for running.
RUN/STOP
External
operation
signal “P1” and “P2”
Overflow sensor
“RUN” lamp
Operation
Button
Setting for running
Set for running
Turning on
Running
Set for stopping
Blinking
Stopping
Setting for stopping
Unrelated
Turning off
How to Run and Stop the Partsfeeder
a.
Estimated cause: The output voltage has been set for “0”.
Remedy: Set the output voltage.
b.
Estimated cause: The output drive frequency of VMC-controller is off the resonance
frequency of the partsfeeder.
Remedy: Adjust it near to the resonance frequency up to get enough stroke.
c.
Estimated cause: VMC-controller stops by “Error”.
Remedy: Resolve the error indicated by “ERROR CODE”. See page 42.
If RUN lamp is not turned on or the partsfeeder does not run even if the RUN lamp is
turned on please check the following items.
When the Run lamp is blinking see the next articles.
2. “RUN/STOP” button, when it is pushed, runs and stops the partsfeeder in turn.
Turning on
Turning off
Push
Stopping
Running
Push
Alarm by blinking “RUN” lamp