![BFC VMC Series Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/bfc/vmc-series/vmc-series_instruction-manual_2746047037.webp)
5
HTE402559
36/47
Applicable wire gauge: AWG28/0.08 sq. mm toAWG20/0.5 sq. mm.
The external diameter must be less than 1.5mm.
Procedure
1.
Remove the covering, 7-8 mm long, according to the “Strip Gauge”
on the connector.
Twist the twisted wire some turns.
2.
Push a white clamp lever into the plug connector
with a minus driver up to lock the lever.
3.
Insert a conductor of a cable deep into the
connector as a covering of the cable is entering the
connector and the conductor has reached clamp port.
How to wire the “E-Con” connector
4.
Insert a minus driver into the release port and pull the
lever back. The lever clamps the conductor with “clap”
sound.
5.
Confirm the levers are released and clamp each conductor.
Pull the cable and the connector lightly with your hands
and you feel light resistance the cable is connected
securely.
Disconnection of the cable
1.
To release the cable push the white clamp lever into
the connector up to lock it.
Then pull off the cable.
2.
Be sure to release the clamp lever after disconnection
of the cable. However, the other cable is going
to be connected do the work as the lever is locked.
Push a white clamp lever